OMAX JetMachining® Center Operator’s Guide
Maintenance
4 - 52
400433D-EN
Software Problems
Also refer to the OMAX Interactive Reference (OIR) for help in troubleshooting software problems.
The mixing tube in the abrasivejet
nozzle is plugged.
In an attempt to dislodge the plug, use Make
to turn the water pump On
and Off. If this fails, you may need to disassemble the nozzle and clean it,
or replace the mixing tube.
The jewel orifice is plugged with
foreign material.
Remove the nozzle and flush the lines. Replace the jewel with a new one.
The pump is not delivering the
pressure specified.
Measure the pressure to see if it is below specification.
Follow the pump troubleshooting procedures.
No high-pressure water yet Make continues to control nozzle as if cutting
Condition and Possible Causes
Corrective Action
No water in white tank or charge
pump pressure has fallen below 50
PSI. Pump display reads “Charge
Pressure Low” followed by “Charge
Pump Contactor”.
Check the source of white tank water supply and verify adequate flow and
pressure. Replace pump water filters if they are restricting flow.
80160 Not Cutting Square Parts
Condition and Possible Causes
Corrective Action
The Y-axis is no longer exactly
perpendicular to the machining table.
Square the Y-axis bridge against the hard stops. You should re-square the
Y-axis whenever:
• The X-axis drive motor faults
• The Y-axis bridge crashes
Keyboard or Mouse Doesn’t Work
Condition and Possible Causes
Corrective Action
Wires or connections in the
computer may have become loose.
Verify that the mouse and keyboard connections in the back of the
Controller PC are firmly inserted.
Blue Screen Errors
Condition and Possible Causes
Corrective Action
Loose USB cable. If the USB cable
is unplugged while Make is running,
the monitor will blue-screen.
Ensure that the USB cable is plugged in adequately. Reboot the
PC.
Using older version of Windows
2000
Update to Service Pack #2 or newer version of Windows 2000.
Corrupt device driver
Simply re-installing OMAX software can fix this. Be sure to fully
power down the controller, wait 10 or more seconds, then turn it
back on for all driver related changes to refresh.
Summary of Contents for JetMachining Center 2626
Page 8: ...OMAX JetMachining Center Operator s Guide viii 400433D EN ...
Page 12: ...OMAX JetMachining Center Operator s Guide xii 400433D EN ...
Page 22: ...OMAX JetMachining Center Operator s Guide Safety First 1 10 400433D EN ...
Page 140: ...OMAX JetMachining Center Operator s Guide OMAX Glossary 6 16 400433D EN ...
Page 144: ...OMAX JetMachining Center Operator s Guide Index 4 400433D EN ...