Safety First
OMAX JetMachining® Center Operator’s Guide
400433D-EN
1 - 7
• Don’t operate the abrasive waterjet for more than a few seconds when the standoff distance
between the water level and nozzle tip is greater than 1.5 inches. Above this height, the entrapped
air can allow the jet stream to easily travel through the water and strike the tank bottom with
sufficient force to cut through it.
Figure 1-6: Sound Level Map of OMAX JetMachining Center
PUMP
CONTROL
TABLE
OPERATOR
STATION
USING dB METER :
REALISTIC SET AT 80 RANGE
WITH SLOW RESPONSE AND
"A" FI LTER SETTING.
CUTTING 1/2" A LUMINUM P LATE
FULLY SUBMERGED.
AMBIENT NOISE WITH NO CU TTING
66d B.
18" FROM CU TTING
HEAD FOR THISTEST.
AVG 82dB
85/86dB PEAK
CUTTING
ZONE
78dB
78dB
79dB
6ft/1.8m
3ft/.9m
9ft/2.7m
9ft/2.7m
6ft/1.8m
3ft/.9m
78dB
78dB
74dB
9ft/2.7m
6ft/1.8m
3ft/.9m
81dB
79dB
78dB
74dB/76dB
78dB/80dB
6ft/1.8m
3ft/.9m
9ft/2.7m
74dB/76dB
1.
2.
3.
NOTES: