Safety First
1 - 8
400433D-EN
Equipment Safety Features
The OMAX equipment provides several built-in safety features:
1.
Emergency Stop Switch
: Both the pump unit and controller are equipped with an emergency stop
switch. Push in the emergency stop switch to immediate shut down both the pump unit and the
abrasivejet.
2.
Overpressure Protection
: The pump has two types of overpressure protection. A factory set
mechanical safety valve provides a hard-plumbed, overpressure limit. The electronics for controlling
the pump also monitor system water pressure. Whenever it detects that the system pressure has
exceeded the factory set pressure limit, it stops the pump and displays 'Dead head of Pump' on the
pump display panel.
3.
Electrical Protection
: The variable frequency drive (VFD) provides electrical protection as well as
speed control for the pump’s main drive motor. A circuit breaker provides short circuit protection for the
charge pump motor. Circuit breakers protect the internal transformer and a 0.5 Amp fuse protects the
pump keypad.
4.
Access Control Circuit
: An optional OMAX Access Control Circuit (ACC) is available for all OMAX
tables. The ACC creates a designated safety zone around the OMAX JetMachining Center that
protects operators from injury when using the OMAX equipment. The access control circuitry
continually monitors two external switch contacts. Opening either switch immediately disables the
cutting process.
Summary of Contents for JetMachining Center 2626
Page 8: ...OMAX JetMachining Center Operator s Guide viii 400433D EN ...
Page 12: ...OMAX JetMachining Center Operator s Guide xii 400433D EN ...
Page 22: ...OMAX JetMachining Center Operator s Guide Safety First 1 10 400433D EN ...
Page 140: ...OMAX JetMachining Center Operator s Guide OMAX Glossary 6 16 400433D EN ...
Page 144: ...OMAX JetMachining Center Operator s Guide Index 4 400433D EN ...