Caution   

 

1.  Open the carton carefully with a knife or paper cutter. 

Find the “UP” sign and place 

the Styrofoam container on the side that makes the arrow upward. If the 

“UP” sign is 

missing, please open the Styrofoam container gently to prevent any accessory, i.e. 
objectives or eyepieces, from dropping and being damaged.   

2.  Do not discard the molded Styrofoam container; the container should be retained 

should the microscope ever requires reshipment.   

3.  Keep the instrument out of direct sunlight, high temperature or humidity, and dusty 

environments. Ensure the microscope is located on a smooth, level and firm 
surface.   

4.  If any specimen solutions or other liquids splash onto the stage, objective or any 

other component, disconnect the power cord immediately and wipe up the spillage. 
Otherwise, the instrument may be damaged. 

5.  All electrical connectors (power cord) should be inserted into an electrical surge 

suppressor to prevent damage due to voltage fluctuations.   

6.  Confirm that the input voltage indicated on your microscope corresponds to your line 

voltage. The use of a different input voltage other than that as indicated will cause 
severe damage to the microscope. 

7. 

Note:

 please read the instruction of the operation of camera in manual 

3.9

 below 

and the CD in the package before you start to use it. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for MD82ES10

Page 1: ...User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet com...

Page 2: ...tents i Caution 1 ii Care and Maintenance 2 1 Components Illustration 3 2 Installation 4 3 Operation 4 4 Specifications 8 5 Troubleshooting Guide 9 6 Darkfield Condenser Installation and Operation Ins...

Page 3: ...ments Ensure the microscope is located on a smooth level and firm surface 4 If any specimen solutions or other liquids splash onto the stage objective or any other component disconnect the power cord...

Page 4: ...ng an excessive amount of solvents as this may cause problems with optical coatings or cemented optics or the flowing solvent may pick up grease making cleaning more difficult Oil immersion objectives...

Page 5: ...ve 17 Power Switch 6 Slide Holder 18 Brightness Intensity Dial 7 Mechanical Stage 19 Abbe Condenser 8 Light Collector 20 Condenser Lock Thumb Screw 9 Microscope Base 21 Condenser Control Knob 10 Viewi...

Page 6: ...n 6 Dry Darkfield Condenser Installation Operation Instruction 3 Operation 3 1 Adjusting illumination 1 Plug the power cord into the power socket on the microscope and connect it to the power outlet 2...

Page 7: ...same specimen into clear sharp focus by adjusting the diopter ring on left eyepiece tube only Do not use focus knobs at this step 5 Since both sides are adjustable you may also do the above in the op...

Page 8: ...When you use the 100X objective to observe the specimen you have to apply the immersion oil on the top of the slide cover When you apply the immersion oil with the 100X objective do not let the immers...

Page 9: ...back of viewing head and the other end to the computer 3 Turn on the computer install the camera following the manual in the mini CD 4 Open image observing software to examine more details see camera...

Page 10: ...Condenser Abbe NA 1 25 w iris diaphragm and diffusion filter Rack and pinion adjustment Focus Mechanism Coaxial coarse and fine focusing knobs on both sides with rack stop Mechanical Stage Double laye...

Page 11: ...get focused image No slide cover attached to the slide Attach a 0 17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down speci...

Page 12: ...se the bolt to lock it when needed Note When raising the mechanical stage do not make contact with the objective 2 Centering the dry darkfield condenser Turn the 4X objective to the light path Turn th...