background image

5

Safety and Warranty

• 

Unplug the unit from the electrical outlet before cleaning or making repairs.

• 

Setting the temperature controls to the 0 (zero) position does not remove power to the light circuit, 

perimeter heaters or evaporator fans.

NOTE:

 It is strongly recommended that any servicing be performed by an authorized instructions before it is 

used.

ELECTRICAL SAFETY

Do not under any circumstances cut or remove the grounding prong from the power cord. For safety this 

appliance must be properly grounded at all times.

•  The power cord of this cooler is equipped with a grounding plug which mates with a standard grounding 

wall outlet to minimize the possibility of electric shock hazard.

•  If the outlet is a standard 2-prong outlet, it must be replaced with the properly grounded wall outlet. NEVER 

USE AN ADAPTER PLUG!

•  Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly 

grounded. Check the incoming voltage with a voltmeter.

•  DO NOT USE EXTENSION CORDS. The use of extension cords to connect the cooler will void warranty. 

The unit must be close enough to the electrical supply so that extension cords are never used.

•  The cooler should always be plugged into its own dedicated circuit with a voltage rating that matches the 

rating plate. This provides the best performance and also prevents overloading wiring circuits which could 

become a fire hazard from overheated wires.

•  Never unplug your cooler by pulling on the power cord. Always grip the plug firmly and pull straight out from 

the outlet.

•  Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use 

a power cord that has cracks or abrasion damage along its length or at either of its ends.

•  When removing the cooler away from the wall be careful not to run over or damage the power cord.

•  When the cooler is installed or used,all the packaging (including carton and plastic wrap) should be 

removed.

•  Keep the cooler stable to avoid vibration and noise.

•  The cooler should be installed in a place with good ventilation and a space of at least 4” should be allowed 

between the surrounding walls and the cabinet wall for air circulation.

•  Unit should be placed far from any heating source to avoid decrease of refrigeration efficiency.

•  Install the cooler in a dry place to prevent rust from forming on the compartment body, which may affect the 

electrical insulation.

Service must only be performed by an authorized service representative, please call Omcan for a local 

service company.

NOTE:

 Wiring diagram can be referenced by removing the front louvered grill, and looking on the inside 

cabinet wall electrical supply so that extension cords are never used.

CAUTION

•  The cooler must be grounded correctly,never with a heating pipe and coal gas pipe.

Summary of Contents for 31861

Page 1: ...Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Back Bar Bottle Coolers Models BB CN 0012 G 0012 S 0016 G 0016 S 0020 G 0020 S Items 31861 37547 31862 37548 31863 37549...

Page 2: ...Information Safety and Warranty Technical Specifications Installation Operation Cleaning and Maintenance Parts Breakdown Electrical Schematics Warranty Registration Model BB CN 0012 G Model BB CN 001...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...ol y que este ha sido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las...

Page 5: ...provides the best performance and also prevents overloading wiring circuits which could become a fire hazard from overheated wires Never unplug your cooler by pulling on the power cord Always grip the...

Page 6: ...om easily climbing inside REFRIGERANT DISPOSAL Your old refrigerator may have a cooling system that used ozone depleting chemicals If you are throwing away your old refrigerator be sure the refrigeran...

Page 7: ...mm 20 x 60 2 x 31 508 x 1529 x 787mm Weight 271 lbs 123 kg 326 lbs 148 kg 355 lbs 161 kg Item Number 31861 31862 31863 SOLID DOOR BOTTLE COOLERS Model BB CN 0012 S BB CN 0016 S BB CN 0020 S Number of...

Page 8: ...y SEALING CABINET TO FLOOR Step 1 Position Cabinet Allow one 1 inch between the wall and rear of the refrigerated bar equipment to assure proper ventilation Step 2 Level Cabinet Cabinet should be leve...

Page 9: ...th the control could lead to service difficulties Should it ever become necessary to replace the temperature control it should be ordered from your dealer or recommended service agent Good air flow in...

Page 10: ...ys the value of the probe set using parameter 4 1 ambient probe default 2 second probe 3 third probe In addition the display has LEDs that indicate the activation of the control functions see Table 1...

Page 11: ...a few moments Increase or decrease the value using UP or DOWN Press SET to confirm the new value Switching the device ON OFF Press UP for more than 3 sec The control and defrost algorithms are now di...

Page 12: ...continuously along with dust lint grease etc If you keep the condenser clean you will minimize your service expense and lower your electrical costs The condenser requires scheduled cleaning every day...

Page 13: ...als on all finishes for grease fatty acids blood and burnt on foods Any good commercial detergent can be applied with a sponge or soft cloth to remove grease and oil Benefit Super Sheen Sheila Shine a...

Page 14: ...ilm on stainless steel 7 Hydrochloric acid muriatic acid should never be used on stainless steel 8 Regularly restore clean stainless steel KEG BEER LINE CLEANING 1 Tools needed 2 Pour cleaning solutio...

Page 15: ...15 Model BB CN 0012 G 31861 Model BB CN 0016 G 31862 Model BB CN 0012 S 37547 Model BB CN 0016 S 37548 Parts Breakdown...

Page 16: ...ator Fan Motor for UBB 48G UBB 48F 08 37707 Lateral Cover of Machine Room for UBB 48G UBB 48F 26 37734 Plate of Lock for Right Door for UBB 48G UBB 48F 37 37691 Evaporator Cover for UBB 48G UBB 48F 09...

Page 17: ...ator Fan Motor for UBB 60G UBB 60F 08 37707 Lateral Cover of Machine Room for UBB 60G UBB 60F 26 37734 Plate of Lock for Right Door for UBB 60G UBB 60F 37 37691 Evaporator Cover for UBB 60G UBB 60F 09...

Page 18: ...18 Parts Breakdown Model BB CN 0020 G 31863 Model BB CN 0020 S 37549...

Page 19: ...Solid Door for UBB 72G UBB 72F 33 37689 Evaporator Fan Motor Holder for UBB 72G UBB 72F 07 37705 Condenser Fan Motor for UBB 72G UBB 72F 22 37731 Upper Right Hinge for UBB 72G UBB 72F 34 37690 Blade o...

Page 20: ...20 Electrical Schematics Model BB CN 0012 G 31861 Model BB CN 0012 S 37547...

Page 21: ...21 Model BB CN 0016 G 31862 Model BB CN 0016 S 37548 Electrical Schematics...

Page 22: ...22 Electrical Schematics Model BB CN 0020 G 31863 Model BB CN 0020 S 37549...

Page 23: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or Email to service omcan com Purchaser s In...

Page 24: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...