Operation
3. Press down the variable control knob and hold for 60 seconds. While holding down the variable control
knob, press the igniter button several times until the pilot flame lights. Release the variable control knob
after the pilot flame lights.
4.
After the pilot flame lights, turn the variable control knob to maximum position and leave it there for 5
minutes or more before turning the knob to the desired temperature position.
NOTE:
•
If a new tank has just been connected, please allow at least one minute for the air in the gas pipeline to
purge out through the pilot hole.
• When lighting the pilot flame make sure that the variable control knob is continuously pressed down while
pressing the igniter button. Variable control knob can be released after the pilot flame is lit.
• Pilot flame can be watched and checked from the small round window with sliding lid located at the bottom
of the flame screen (to the left or right of the controller).
• If the pilot flame does not light or it goes out, repeat step 3.
TO TURN OFF THE HEATER
1. Turn the variable control knob to the PILOT position.
2. Press and turn the variable control knob to the OFF position.
3.
Turn off the valve on the gas supply cylinder completely.
STORAGE
1. Always close the gas valve of the gas cylinder after use or in case of a disturbance.
2. Remove the pressure controller and the hose.
3. Check the tightness of the gas valve and for damage. If you suspect damage, have it changed by your gas
dealer.
4.
Never store liquid gas containers in an underground or inadequately ventilated location.