Installation / Operation

CABINET LOCATION GUIDELINES

•  Install the unit on strong and leveled surfaces. 

- Unit may make unpleasant noises if surface is uneven. 

- Unit may malfunction if surface is uneven.

•  Install the unit in an indoor, well-ventilated area. 

- Unit performs more efficiently in a well-ventilated area. 

- For best performance, please maintain clearance of 4” on the back of the unit. 

- Outdoor use may cause decreased efficiency and damage to the unit.

•  Avoid installation in a high humidity and/or dusty area. 

- Humidity could cause unit to rust and decrease efficiency of the unit. 

- Dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least once a 

month with a brush or clean cloth.

•  Select a location away from heat and moisture-generating equipment. 

- High ambient temperature will cause the compressor to overwork, leading to higher energy bills and 

gradual breakdown of the unit.

ELECTRICAL

Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage 

can detrimentally affect the refrigeration unit. All units should be plugged into a grounded and properly-sized 

electrical outlet with appropriate overcurrent protection. Please refer to the electrical requirement on the 

nameplate. Please make sure that your unit has its own dedicated outlet. Do not use an extension cord.

TEMPERATURE CONTROLS

The temperature controls are factory-set to maintain an average temperature of 38°F in refrigeration. To 

maintain a different temperature, simply adjust the control knob located inside the unit. To decrease the 

temperature (colder), turn clockwise. To increase the temperature(warmer), turn counter-clockwise – see 

diagram.

LOADING PRODUCT

The bin dividers have been installed at the factory for your convenience. Feel free to reposition the dividers 

as you see fit. To remove the bin dividers, simply push the divider towards the back wall unit the front of the 

divider is removed from the positioning holes. To install, position the divider to the desired holes, making sure 

that the pressure spring is installed properly.

PAY CLOSE ATTENTION TO THE LOAD LIMIT STICKERS LOCATED ON THE INTERIOR WALLS TO THE 

UNIT. DO NOT LOAD PRODUCT ABOVE THE LOAD LIMIT STICKERS OR ABOVE THE TOP CROSS BAR 

OF THE BIN DIVIDERS. LOADING PRODUCT ABOVE THE LOAD LIMIT STICKERS WILL HARM THE 

PERFORMANCE OF THE UNIT.

Summary of Contents for BB-CN-0005

Page 1: ...each In Bottle Coolers Models BB CN 0005 0014 0017 0026 Items 42945 31859 31860 42946 Instruction Manual Revised 02 24 2017 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com ...

Page 2: ...ntents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Model BB CN 0005 Model BB CN 0014 Model BB CN 0017 Model BB CN 0026 ...

Page 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Page 4: ...ar daños externos Si no hay daños evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas de modo que pod...

Page 5: ...rical cord and plug To minimize personal injury do not hang on the doors Do not store any flammable and explosive gas or liquids inside the unit Do not attempt to alter or tamper with the electrical cord Do not set the desired temperature out of the recommended temperature range Ref 32 F 50 F 1 YEAR PARTS AND LABOUR WARRANTY Within the warranty period contact Omcan Inc at 1 800 465 0234 to schedul...

Page 6: ...13 5 cu ft 488 L 17 23 cu ft 730 L 25 8 cu ft Temperature Range 0 5 C 33 41 F 0 10 C 32 50 F 0 5 C 33 41 F Electrical 115V 60Hz Amps 1 42A 8A 8 5A 8 9A Refrigerant R134a Isolation Material Cyclopentane Cooling System Ventilated Defrosting Automatic Dimensions DWH 711 x 645 x 870mm 28 x 25 4 x 34 25 711 x 1257 x 870mm 28 x 49 5 x 34 25 711 x 1638 x 870mm 28 x 64 5 x 34 25 711 x 2419 x 870mm 28 x 95...

Page 7: ...t All units should be plugged into a grounded and properly sized electrical outlet with appropriate overcurrent protection Please refer to the electrical requirement on the nameplate Please make sure that your unit has its own dedicated outlet Do not use an extension cord TEMPERATURE CONTROLS The temperature controls are factory set to maintain an average temperature of 38 F in refrigeration To ma...

Page 8: ...amage CLEANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel Installation Operation CAUTION Setting the temperature control to the coldest setting may cause the Evaporator coil to freeze and ice up This will eventually result in a warmer Cabinet tem...

Page 9: ...ms PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Power cord unplugged Plug in power cord Thermostat set too high Set thermostat to lower Temperature Cabinet in defrost cycle Wait for defrost cycle to finish Condensing unit runs for long periods of time Excessive amount of warm product Placed in cabinet Al...

Page 10: ...are closed when not in use Avoid opening doors for long periods of time Evaporator coil iced over See above Cabinet is noisy Loose part s Locate and tighten loose part s Tubing vibration Ensure tubing is free from contact with other tubing or components For service call 1 800 465 0234 REFERENCE Item Number Model Number Description Manufacturer Model Number 42945 BB CN 0005 Cooler Back Bar 5 cu ft ...

Page 11: ...11 Model BB CN 0005 42945 Parts Breakdown ...

Page 12: ...6776 Condenser Fan Motor for JBC25 39 37753 Rivet for JBC25 8 71996 Interior Water Tray for JBC25 24 28254 Condenser Fan Blade for JBC25 40 37754 Limited Block for JBC25 9 71997 Cabinet for JBC25 25 28256 Condenser Fan Cover for JBC25 41 71989 Left Track of Compressor Mounting Plate for JBC25 10 37778 Right Plate of Evaporator Cover for JBC25 26 37791 Filter D25x140 for JBC25 42 71990 Right Track ...

Page 13: ...13 Model BB CN 0014 31859 Parts Breakdown ...

Page 14: ...Inner Plate of Collecting Box 36 37749 Door 06 37769 Left Plate of Evaporator Cover 20 37787 Collecting Box of Bottle Cap 37 37751 Door Handle 07 37770 Evaporator Cover 21 37788 Condenser Fan Motor 39 37752 Door Seal 08 37772 Evaporator Fan Cover 22 37789 Condenser Fan Blade 40 37754 Limited Block 09 37773 Evaporator Fan 23 37790 Condenser Fan Cover 41 37755 Shelf 10 37774 Interior Water Tray 24 3...

Page 15: ...15 Model BB CN 0017 31860 Parts Breakdown ...

Page 16: ...Inner Plate of Collecting Box 36 37750 Door 06 37769 Left Plate of Evaporator Cover 20 37787 Collecting Box of Bottle Cap 37 37751 Door Handle 07 37771 Evaporator Cover 21 37788 Condenser Fan Motor 39 37753 Door Seal 08 37772 Evaporator Fan Cover 22 37789 Condenser Fan Blade 40 37754 Limited Block 09 37773 Evaporator Fan 23 37790 Condenser Fan Cover 41 37755 Shelf 10 37775 Interior Water Tray 24 3...

Page 17: ...17 Model BB CN 0026 42946 Parts Breakdown ...

Page 18: ...JBC95 7 37773 Evaporator Fan for JBC95 23 37788 Condenser Fan Motor for JBC95 39 37753 Rivet for JBC95 8 72008 Interior Water Tray for JBC95 24 37789 Condenser Fan Blade for JBC95 40 37754 Limited Block for JBC95 9 72009 Cabinet for JBC95 25 37790 Condenser Fan Cover for JBC95 41 37755 Shelf for JBC95 10 37778 Right Plate of Evaporator Cover for JBC95 26 37791 Filter D25x140 for JBC95 42 37756 Spr...

Page 19: ...19 Electrical Schematics Model BB CN 0005 42945 ...

Page 20: ...20 Electrical Schematics Model BB CN 0014 31859 ...

Page 21: ...21 Electrical Schematics Model BB CN 0017 31860 ...

Page 22: ...22 Electrical Schematics Model BB CN 0026 42946 ...

Page 23: ...ister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or Email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Cater...

Page 24: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 3500 produ...