7
Installation / Operation
CABINET LOCATION GUIDELINES
• Install the unit on strong and leveled surfaces.
- Unit may make unpleasant noises if surface is uneven.
- Unit may malfunction if surface is uneven.
• Install the unit in an indoor, well-ventilated area.
- Unit performs more efficiently in a well-ventilated area.
- For best performance, please maintain clearance of 4” on the back of the unit.
- Outdoor use may cause decreased efficiency and damage to the unit.
• Avoid installation in a high humidity and/or dusty area.
- Humidity could cause unit to rust and decrease efficiency of the unit.
- Dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least once a
month with a brush or clean cloth.
• Select a location away from heat and moisture-generating equipment.
- High ambient temperature will cause the compressor to overwork, leading to higher energy bills and
gradual breakdown of the unit.
ELECTRICAL
Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage
can detrimentally affect the refrigeration unit. All units should be plugged into a grounded and properly-sized
electrical outlet with appropriate overcurrent protection. Please refer to the electrical requirement on the
nameplate. Please make sure that your unit has its own dedicated outlet. Do not use an extension cord.
TEMPERATURE CONTROLS
The temperature controls are factory-set to maintain an average temperature of 38°F in refrigeration. To
maintain a different temperature, simply adjust the control knob located inside the unit. To decrease the
temperature (colder), turn clockwise. To increase the temperature(warmer), turn counter-clockwise – see
diagram.
LOADING PRODUCT
The bin dividers have been installed at the factory for your convenience. Feel free to reposition the dividers
as you see fit. To remove the bin dividers, simply push the divider towards the back wall unit the front of the
divider is removed from the positioning holes. To install, position the divider to the desired holes, making sure
that the pressure spring is installed properly.
PAY CLOSE ATTENTION TO THE LOAD LIMIT STICKERS LOCATED ON THE INTERIOR WALLS TO THE
UNIT. DO NOT LOAD PRODUCT ABOVE THE LOAD LIMIT STICKERS OR ABOVE THE TOP CROSS BAR
OF THE BIN DIVIDERS. LOADING PRODUCT ABOVE THE LOAD LIMIT STICKERS WILL HARM THE
PERFORMANCE OF THE UNIT.
Summary of Contents for BB-CN-0005
Page 11: ...11 Model BB CN 0005 42945 Parts Breakdown ...
Page 13: ...13 Model BB CN 0014 31859 Parts Breakdown ...
Page 15: ...15 Model BB CN 0017 31860 Parts Breakdown ...
Page 17: ...17 Model BB CN 0026 42946 Parts Breakdown ...
Page 19: ...19 Electrical Schematics Model BB CN 0005 42945 ...
Page 20: ...20 Electrical Schematics Model BB CN 0014 31859 ...
Page 21: ...21 Electrical Schematics Model BB CN 0017 31860 ...
Page 22: ...22 Electrical Schematics Model BB CN 0026 42946 ...