5
Safety and Warranty
• Unplug the unit from the electrical outlet before cleaning or making repairs.
• Setting the temperature controls to the 0 (zero) position does not remove power to the light circuit,
perimeter heaters or evaporator fans.
NOTE:
It is strongly recommended that any servicing be performed by an authorized instructions before it is
used.
ELECTRICAL SAFETY
Do not under any circumstances cut or remove the grounding prong from the power cord. For safety this
appliance must be properly grounded at all times.
• The power cord of this cooler is equipped with a grounding plug which mates with a standard grounding
wall outlet to minimize the possibility of electric shock hazard.
• If the outlet is a standard 2-prong outlet, it must be replaced with the properly grounded wall outlet. NEVER
USE AN ADAPTER PLUG!
• Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly
grounded. Check the incoming voltage with a voltmeter.
• DO NOT USE EXTENSION CORDS. The use of extension cords to connect the cooler will void warranty.
The unit must be close enough to the electrical supply so that extension cords are never used.
• The cooler should always be plugged into its own dedicated circuit with a voltage rating that matches the
rating plate. This provides the best performance and also prevents overloading wiring circuits which could
become a fire hazard from overheated wires.
• Never unplug your cooler by pulling on the power cord. Always grip the plug firmly and pull straight out from
the outlet.
• Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use
a power cord that has cracks or abrasion damage along its length or at either of its ends.
• When removing the cooler away from the wall be careful not to run over or damage the power cord.
• When the cooler is installed or used, all the packaging (including carton and plastic wrap) should be
removed.
• Keep the cooler stable to avoid vibration and noise.
• The cooler should be installed in a place with good ventilation and a space of at least 6” should be allowed
between the surrounding walls and the cabinet wall for air circulation.
• Unit should be placed far from any heating source to avoid decrease of refrigeration efficiency.
• Install the cooler in a dry place to prevent rust from forming on the compartment body, which may affect the
electrical insulation.
It is strongly recommended that any servicing be performed by an authorized service representative.
NOTE:
Wiring diagram can be referenced by removing the front louvered grill, and looking on the inside
cabinet wall electrical supply so that extension cords are never used.
CAUTION
• The cooler must be grounded correctly, never with a heating pipe and coal gas pipe.
• In case of damage to electrical cord and plug, please contact after sale service and never do it yourself.
Summary of Contents for BB-CN-0012-DH
Page 17: ...17 Parts Breakdown Model BD CN 0007 HC 50066...
Page 19: ...19 Parts Breakdown Model BB CN 0012 DH 50063...
Page 21: ...21 Parts Breakdown Model BD CN 0019 HC 50067...
Page 23: ...23 Parts Breakdown Model BB CN 0016 DH 50064...
Page 25: ...25 Parts Breakdown Model BD CN 0023 HC 50068...
Page 27: ...27 Parts Breakdown Model BB CN 0020 DH 50065...
Page 29: ...29 Parts Breakdown Model BD CN 0032 HC 50069...
Page 31: ...31 Electrical Schematics Model BD CN 0007 HC 50066...
Page 32: ...32 Electrical Schematics Model BB CN 0012 DH 50063...
Page 33: ...33 Model BD CN 0019 HC 50067 Electrical Schematics...
Page 34: ...34 Model BB CN 0016 DH 50064 Electrical Schematics...
Page 35: ...35 Model BD CN 0023 HC 50068 Electrical Schematics...
Page 36: ...36 Electrical Schematics Model BB CN 0020 DH 50065...
Page 37: ...37 Electrical Schematics Model BD CN 0032 HC 50069...