SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Pilot will not light.
Gas supply off.
Check main / unit gas valves.
Air in lines.
Turn pilot valve on. Attempt to light
pilot every 15 sec.
Pilot valve not on.
Turn pilot valve on / adjust.
Burners won’t light.
Gas supply off.
Check main / unit gas valves.
Air in lines.
Turn gas valve on. Attempt to light
pilot every 15 sec.
Pilot valve not lit.
Turn off gas - allow unit to vent for
5 minutes. Turn gas back on and
light pilot.
Front or rear burner won’t light.
Control not on.
Turn temperature control to ON.
Set to desired setting when lit.
Water in burner.
Remove burner and dry thoroughly.
Damaged temperature control,
Burner or other internal
component.
Contact Authorized Omcan Service
Agency for repairs.
Burner not hot enough.
Temperature control not set.
Adjust for desired temperature.
Shutter or nozzle out of
adjustment.
Contact qualified technician for
adjustment.
Damaged temperature control,
burner or other internal
component.
Contact Authorized Omcan Service
Agency for repairs.