background image

Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North 

American food service industry. Our success over these many years can be attributed to our commitment 

to strengthen and develop new and existing relationships with our valued customers and manufacturers. 

Today with partners in North America, Europe, Asia and South America, we continually work to improve 

and grow the company. We strive to offer customers exceptional value through our qualified local sales 

and service representatives who provide convenient access to over 3,500 globally sourced products.

Depuis 1951 Omcan a grandi pour devenir un des “leaders” de la distribution des équipements et  

matériel pour l’industrie des services alimentaires en Amérique du Nord. Notre succès au cours de ces 

nombreuses années peut être attribué à notre engagement à renforcer et à développer de nouvelles 

et existantes relations avec nos clients et les fabricants de valeur. Aujourd’hui avec des partenaires en 

Amérique du Nord, Europe, Asie et Amérique du Sud, nous travaillons continuellement à améliorer et 

développer l’entreprise. Nous nous efforçons d’offrir à nos clients une valeur exceptionnelle grâce à 

nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 3500 

produits provenant du monde entier.

Desde 1951 Omcan ha crecido hasta convertirse en un líder en la distribución de equipos y suministros 

de alimentos en América del Norte industria de servicios. Nuestro éxito en estos años se puede atribuir 

a nuestro compromiso de fortalecer y desarrollar nuevas relaciones existentes con nuestros valiosos 

clientes y fabricantes. Hoy con socios de América del Norte, Europa, Asia y América del Sur, que trabajan 

continuamente para mejorar y crecer la empresa. Nos esforzamos por ofrecer a nuestros clientes valor 

excepcional a través de nuestro local de ventas y representantes de los servicios que proporcionan un 

fácil acceso a más de 3,500 productos con origen a nivel mundial.

Summary of Contents for CE-CN-0640-S

Page 1: ...Revised 7 24 2015 Toll Free 1 800 465 0234 Fax 905 607 0234 Email sales omcan com www omcan com Gas Stock Pot Burners Models CE CN 0640 S 1060 S Items 37525 37529 Instruction Manual...

Page 2: ...e of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Instructions for Field Conversion between LP NG Parts Breakdown Notes Warranty...

Page 3: ...s saine d esprit et pas sous l influence d une drogue ou d acohol qui a t form pour utiliser cette machine correctement et est v tu de v tements de s curit appropri Toute modification de la machine an...

Page 4: ...e instructions provided by the gas supplier Do not try to light the burner do not use a telephone within close proximity Never attempt to move grate while cooking 1 YEAR PARTS AND LABOUR WARRANTY With...

Page 5: ...9 x 24 4 455 x 1064 x 620mm 17 9 x 41 9 x 24 4 Item Number 37525 37529 Please see www omcan com warranty html for complete info WARNING The packaging components are classified as normal solid urban w...

Page 6: ...3 5 kPa CLEARANCE AND POSITIONING AROUND EQUIPMENT This equipment must be installed adjacent to non combustible surfaces only with a minimum spacing of 6 from all sides This equipment must be a distan...

Page 7: ...to the equipment and wait 5 minutes to clear the gas 2 Turn off all gas control knobs 3 Turn on control valve and light all pilots 4 The pilot burner must be lit at the end of the tube Hold an igniti...

Page 8: ...any should check the unit for safe and efficient operation on an annual basis Gas piping shall be a certain size and installed to provide a supply of gas sufficient to meet the full gas input of the e...

Page 9: ...uthorized service agent In case of troubleshooting ensure the correct orifice sizes of the spuds have been provided Natural Gas Orifice is 31 Liquid Propane Gas Orifice is 52 Orifice size is marked on...

Page 10: ...over the orifice and then locating the M5 stud through the slot in the support bracket Secure by replacing the M5 nut 7 To operate with LP gas the regulator must be changed to operate at 10 WC To do...

Page 11: ...he screws holding the front panel and remove 2 The pilot burner valve is positioned to the right of the control valve a small adjustment screw is located on the front face of the valve body This can b...

Page 12: ...12 Parts Breakdown Model CE CN 0640 S 37525...

Page 13: ...e Feet Support for THRB1 21 70225 THRB1 04 Gas Valve for THRB1 4 70234 THRB1 13 Body Back for THRB1 13 70243 THRB1 22 Lower Body Panel for THRB1 22 70226 THRB1 05 Join Part for THRB1 5 70235 THRB1 14...

Page 14: ...14 Parts Breakdown Model CE CN 1060 S 37529...

Page 15: ...RB2 14 Join Part for THRB2 14 70271 THRB2 24 M16 x 1 25 Nut with Dia 10 for THRB2 24 70252 THRB2 05 Body Sides Support for THRB2 5 70262 THRB2 15 Connection Pipe Long for THRB2 15 70272 THRB2 25 Drip...

Page 16: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 17: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...specified below You can also register online by visiting OMCAN INC PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html Purc...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: