Trouble Shooting
Breakdown
Case
Removal method
The indicator is not on.
The compressor doses not
start.
The plug isn
’t connected to
the socket fully.
Push plug fully in.
no power
Connect the socket with
power.
The indicator is on ,but the
compressor does not start,
buzzes only
The power voltage is
<
98V.
Provide proper voltage
The compressor stops a
minute after start, and
restart after a few minutes,
and so repeatedly.
The power voltage is
>
132V.
The compressor works
normally, but the
temperature in the cabinet
lowers too slowly.
The door is opened too
frequently.
Reduce open times.
The food in the cabinet is
placed improperly.
Place foods properly,
keeping space for
ventilation.
The frost film is too thick.
Take out foods and defrost.
The surface of the
condenser is too dirty.
Stop and clean the
condenser.
The door seals badly.
Adjust the door seal.
The noise is too loud
The freezer is placed
unstably.
Place it stably.
The fixing of the freezer is
loose.
Tighten the fixing.
There
’s contact between
pipes.
Separate them.
The following are not faults:
l
The refrigerant pipes may give off a
“running water” sound.
l
The surface temperature of the compressor may be up 70°~80° when it is
working.
l
The back side of freezer gives out heat.
l
In high humidity location, the outer surface of the cabinet may have
condensation.