12
Operation
Notice: The screw position of ice thickness sensor determines the distance between the sensor reeds
and evaporator plate. The standard gap space should be range of 4mm-7mm, please keep gap space
properly.
Caution: Do not adjust the gap out of manufactory required standard. Improper adjustment are not
cover by warranty.
WARNING
•
This ice maker produces and stocks ice for use. To keep the ice maker clean and sanitary, the
requirements are as follows:
- Wash your hands before taking ice and use special ice shovel.
- The ice maker is only used for production and storage of ice, do not store any other items in it.
- The ice storage bin should be cleaned before use.
- Keep the ice shovel clean. Please wash the ice shovel with neutral detergent and clean water.
- Close the sliding door of ice storage bin after taking the ice, to prevent dirt and dust from getting into the
ice storage bin.
•
Please follow the basic principles while using any electrical device, points to note:
- High humidity will increase the electrical circuit and potential risk of electric shock. If any doubt, please
disconnect the ice maker from electrical power.
- Don’t pull the power cord vigorously.
- The ice maker is not suitable for use by unattended children, the elderly or disabled.
• After shutting off the ice maker, you should wait at least 3 minutes before restart, in order to avoid any
damage to the compressor.
ICE MAKER START UP
Ice maker has been a pre-set 3 minutes cleaning programme which starts automatically after machine is
switched on.
After cleaning programme, it switches over to ice making mode automatically.
ICE MAKER PROCESSING
The water pump of ice maker will start work after water level reaches the position of high water position switch.
When water level reaches low water position switch, the ice making program will start.