2.  Clean the ice bin and the food area inside with a sponge soaked in warm water and soda. Then wash and 

dry it with potable water.

3.  Place the ice machine in the operation area; ensure that the machine is placed on a leveled floor. So as to 

ensure the water flows evenly on the evaporator.

4.  The compressor chamber is located at the back. The compressor and condenser are installed in it. For air 

cooled unit, it requires good ventilation. Therefore, the front and rear of the ice maker must have ventilation 

space of more than 20-30 cm.

5.  The bottom of the ice machine is equipped with adjustable legs for level adjustment and floor cleaning.

6.  Connect the machine’s inlet water filter and water pipe referring to the schematic diagram of installation; if 

the installation site is already equipped with a drinking water system, the water filter may not be installed. 

Note: the filter flow direction should be correctly installed as per the direction marker on the filter 

head cover or the filter body. 

Note: This machine is equipped with an inlet water filter. The filter will keep impurities from the 

water used as the machine is running. Generally, it needs to be replaced every month to every 3 

months.

7.  Connect the machine to the water supply using the 3/4” inlet pipe supplied with the machine. It is 

recommended to install a water valve (not supplied with this machine) on the water supply line.

8.  Connect the drain pipe to the drain connection. In order to meet a good draining, it is recommended that 

the drain pipe should have a difference of level more than 3cm per meter; and confirm that the drain pipe is 

not blocked. It is recommended that the drain pipe be connected to an open drainage port.

9.  Any joint in the drain pipe must not be higher than the machine drainage port; any joint in the drain pipe 

cannot be higher than the previous joint.

10. Confirm the power requirements stated in the machine nameplate; ensure that the power supply meets the 

requirements.

11. A circuit breaker or switch with leakage protector and reliably grounding is required.

12. Turn off the switch on the power line and connect the machine to the power source.

STARTUP AND OPERATION

1.  Before you start up the machine, please check and confirm: 

• That the packaging tape inside the ice machine has been removed. 

• The accessories or items in the ice bin have been taken out. 

• The ice machine has been adjusted to a leveled state. 

• The water pipe has been connected and the water valve is open. 

• The plug has been connected to the power supply and the power switch is off. 

• The ambient temperature, water temperature, and pressure of the water supply meet the above 

requirements.

2.  Start up: turn on the power switch. After power-on, the machine begins to make ice automatically.

3.  For normal operation, please confirm: 

• There is water in the water trough and no overflow occurs. 

Summary of Contents for IC-CN-0129S

Page 1: ...Revised 06 03 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Ice Maker Model IC CN 0129S 0219S 0329 0529 Items 47483 47484 47485 46452 Instruction Manual...

Page 2: ...s Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registrati...

Page 3: ...GES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE WICKING PAD IS NOT REPLACED EVERY SIX MONTHS AND IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio Omcan favor inspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton...

Page 6: ...a hazardous voltage There is a risk of electric shock This label indicates a hazardous voltage There is a risk of electric shock This label indicates rotating components inside There is a risk of ser...

Page 7: ...result in explosion or fire Do not store any sundries or freeze any food in the ice bin Keep the ice scoop clean The ice machine must be placed on the floor sufficient to supports its weight Insuffici...

Page 8: ...ilar occasions The kitchen area of a store office or other workplace Farm hotel car hotel and restaurant Catering and similar non retail occasions This ice machine is not intended for used at home RES...

Page 9: ...tem Number 47483 47484 47485 46452 The ice machine should be installed in a proper location meeting the following conditions Indoor not more than 2 000 meters above sea level Ambient temperature canno...

Page 10: ...ded to install a water valve not supplied with this machine on the water supply line 8 Connect the drain pipe to the drain connection In order to meet a good draining it is recommended that the drain...

Page 11: ...h power on for the first time the ice maker will do self check and pump out remaining water Preparing after the ice machine is energized the inlet valve opens and water will come inside the machine un...

Page 12: ...minutes 4 Cleaning During the normal operation hold the cleaning button for 3 seconds to enter the cleaning process During the entire cleaning process cleaning agents and disinfectants need to be put...

Page 13: ...nce INLET WATER FILTER The filter element should be inspected regularly It is recommended to replace filter element every month to every 3 months INTERIOR CLEANING The inside of the ice storage bin ca...

Page 14: ...t 15 minutes Please do spray sterilizing to the evaporator at the mean time to insure a complete sterilizing When finished the ice maker will get into rinsing process the process will take about 5 min...

Page 15: ...t the defrosting valve Ice thickness too thin or too thick Check and correct ice thickness setting Poor transparency of ice cubes ice cubes too thin or incomplete Ice thickness too thin Check and corr...

Page 16: ...water curtain is reset E03 Ice Harvest Overtime Sleeping mode E04 High Temp Fault Sleeping mode E05 Water Shortage Fault Sleeping mode and retry every 30 mins E06 Over Pressure Fault Sleeping mode E07...

Page 17: ...17 Parts Breakdown Model IC CN 0129S 47483...

Page 18: ...7 AC885 PC Board for 47483 29 AK041 Filter Left Card Slot for 47483 6 AK053 Silicone Hose for 47483 18 AK060 LED Lamp Reed Tube Magnetic Switch for 47483 30 AK042 Filter Right Card Slot for 47483 7 AC...

Page 19: ...19 Model IC CN 0219S 47484 Parts Breakdown...

Page 20: ...Frame Assembly Black Gray for 47484 5 AC882 Defrost Valve Coil for 47484 17 AK077 Filter Right Card Slot for 47484 29 AK044 Cold Light for 47484 6 AK053 Silicone Hose for 47484 18 AK078 Filter Left Ca...

Page 21: ...21 Model IC CN 0329 47485 Parts Breakdown...

Page 22: ...485 4 AC884 Ventilation Window Filter for 47485 14 AC894 Water Pump for 47485 24 AC875 Inlet Valve for 47485 5 AC885 PC Board for 47485 15 AC895 Water Level Water Temperature Sensor for 47485 25 AC876...

Page 23: ...23 Model IC CN 0529 46452 Parts Breakdown...

Page 24: ...on Item No Description Position Item No Description Position AC872 Microchannel Condenser for 46452 1 AC882 Defrost Valve Coil for 46452 11 AC892 Ice Full Sensor for 46452 21 AC873 Fan for 46452 2 AC8...

Page 25: ...25 Model IC CN 0129S 47483 Model IC CN 0219S 47484 Model IC CN 0329 47485 Model IC CN 0529 46452 Electrical Schematics...

Page 26: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 27: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 28: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: