12
Operation
If relighting a hot heater, always wait at least 5 minutes.
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should
be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose
assembly specified by manufacturer.
LIGHTING
NOTE:
This heater is equipped with a pilot light that allows for safer startups and shutdowns. Pilot must be lit
before main burner can be started.
1. Turn the control knob to the “OFF” position.
2. Fully open LP cylinder valve.
3.
Open viewing hole by sliding cover to either side.
4. Push control knob in and rotate to pilot position.
NOTE:
For initial start or after any cylinder change, hold control knob in for 2 minutes to purge air from gas
lines before proceeding.
5. Push and release the igniter button until pilot flame is visible through viewing hole.
6. Once the pilot is lit, continue to depress the control knob for 30 seconds.
7.
If the pilot does not stay lit, repeat steps 4 to 6.
8.
If after repeating steps 4 to 6 unit does not light, then:
- Push in control knob and turn counterclockwise to “PILOT”.
- As you are depressing the control knob, place long stem lighter into the ignition hole on the emitter screen
to light the pilot.
- Repeat step 7.
9. Push in and turn the control knob to the “LOW”, then release control knob. If you want a higher
temperature, push in the control knob and turn counterclockwise to the “HIGH”.
NOTE:
If pilot fails to remain lit, all valves should be closed and a waiting period of at least 5 minutes should
pass before attempting to light.
WHEN HEATER IS ON
Emitter screen will become bright red due to intense heat. The color is more visible at night. Burner will display
tongues of blue and yellow flame. These flames should not be yellow or produce thick black smoke, indicating
an obstruction of airflow through the burners. The flame should be blue with straight yellow tops. If excessive
yellow flame is detected, turn off heater and consult “Troubleshooting”.
RE-LIGHTING
NOTE:
For your safety, control knob cannot be turned OFF without first depressing control knob in PILOT
position and then rotating it to OFF.
1.
Turn control knob to OFF.
2.
Wait at least 5 minutes, to let gas dissipate, before attempting to relight pilot.
3. Repeat the “Lighting” steps on prior page.