16

Item No. Description

Position

Item No. Description

Position

Item No. Description

Position

63148

Reflector Panel with Plate for HSSADSS

A + B

63155

Cylinder Housing with Preassembled 

Door for HSSADSS

H + I

63162

Wheel Kit for HSSADSS

O

63150

Head Assembly with Gas Hose and 

Regulator for HSSADSS

C + K + L

63157

Post for HSSADSS

J

63151

Screw Coupler with Table Assembly for 

HSSADSS

D + E + F 

+ G

63160

Complete Base for HSSADSS

M + N

Caution: Use only original Omcan replacement parts. Use of unauthorized parts or modification of parts will 

void warranty and create an unsafe condition.

Always allow heater to cool before attempting service.

Troubleshooting

Gas odor with extreme yellow 

tipping of flame.

Spiders and insects nest in burner or 

orifices.

Clean burner and orifices.

Heater glow is excessively 

uneven.

Spiders and insects nest in burner or 

orifices.

Clean burner and orifices.

Heater makes popping noises.

Spiders and insects nest in burner or 

orifices.

Clean burner and orifices.

Carbon build-up.

Dirt or film on reflector and burner 

screen.

Clean reflector and burner screen.

REFERENCE

Item Number Model Number

Description

Manufacturer Model Number

43595

PH-CN-0014

Patio Heater 87” / 2210mm with Tank Door 

and Table One Piece Reflector 41000 BTU 

Stainless Steel Propane

HSSADSS

Parts Breakdown

Model PH-CN-0014 

43595

Summary of Contents for PH-CN-0014

Page 1: ...Patio Heater Model PH CN 0014 Item 43595 Instruction Manual Revised 04 18 2018 Factory CSA approved Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...14 15 15 16 16 17 18 19 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Re...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...ido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la...

Page 5: ...e wind velocity is greater than 10 miles per hour Unit will operate at reduced efficiency below 40 F 5 C It is normal for the heater to make hissing sounds at the start This will decrease as the heate...

Page 6: ...valves can be quickly identified by their external and internal threads The cylinder must be provided with a shutoff valve termination in an LP gas supply cylinder valve outlet specified as applicabl...

Page 7: ...ss Steel Safety Features 100 Burner Shut Off Heat Range Up to 20 foot diameter Inlet Gas Supply Pressure Maximum 10 5 W C Minimum 7 0 W C Fuel Use propane or butane gas only Gas Supply Pressure 120 PS...

Page 8: ...using the reinforced ring NN M6 x 10 mm bolts DD and 6 small flat washers EE Fasten and cover with the deck ring OO 5 Slide fastening nut G down the post J with the rounded side facing down Next slide...

Page 9: ...0 Remove protective cover from reflector panel A and reflector plate B Note In order to achieve proper alignment of reflector sections it may be necessary to loosen the preassembled bolts prior to ass...

Page 10: ...nder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the standard for cylinders spheres and tubes for transport...

Page 11: ...regulator connection This part is defective and you should contact the customer service department for replacement If NO bubbles appear at any connection the connections are secure NOTE Whenever gas c...

Page 12: ...ight then Push in control knob and turn counterclockwise to PILOT As you are depressing the control knob place long stem lighter into the ignition hole on the emitter screen to light the pilot Repeat...

Page 13: ...ns noted All components are properly assembled intact and operable No alterations have been made All gas connections are secure and do not leak Wind velocity is below 10 mph Unit will operate at reduc...

Page 14: ...ler particles Carbon deposits may create a fire hazard Clean dome and burner screen with warm soapy water if any carbon deposits develop NOTE In a salt air environment such as near an ocean corrosion...

Page 15: ...stay lit Dirt built up around pilot Clean dirt from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and perform leak check Thermocouple is not operating corre...

Page 16: ...an unsafe condition Always allow heater to cool before attempting service Troubleshooting Gas odor with extreme yellow tipping of flame Spiders and insects nest in burner or orifices Clean burner and...

Page 17: ...17 Parts Breakdown Model PH CN 0014 43595...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: