background image

5

Safety and Warranty

installed, tested and serviced by qualified personnel only. Any adjustment whatsoever not expressly authorized 

and in disrespect of this manual voids the warranty. Observe all existing local regulations at the time of 

installation. Check that the characteristics of the electric grid correspond to the data given on the serial plate 

of the appliance. The packing materials (plastic bags, polystyrene, nails, etc.) as potential hazards, must be 

kept out of the reach of children and properly recycled according to the existing local regulations. For repairs 

contact Omcan and request the use of original spare parts. If in doubt do not use the appliance and contact 

Omcan. Not following the above conditions could risk the safety of those using the unit.

FOR YOUR SAFETY

Improper instillation, adjustment, alteration, service or maintenance can cause serious injury or property 

damage. Keep heater away from areas where flammable liquids, gasoline, vapors or explosives are stored 

or used. Gas leaks may cause a fire or explosion which can cause damage to property, serious bodily injury 

or death. Follow all leak-checking procedure before operating this unit highlighted in Step 8. If you smell gas: 

shut off gas to appliance, extinguish any open flame and if odor continues, contact your gas supplier or local 

fire department. This unit consumes air provide 1 inch² of opening for fresh air for each 1,000 Btu/Hr Input 

(2.22mm² / Wof Input). Never use open flame to check for leaks. Fuel systems must be installed by qualified 

and licensed personnel. Please contact your local gas supplier for these services.

•  Always maintain at least 18” clearance (top) and 24” clearance (side) from combustible materials. 

• 

Always place the heater on a hard a hard leveled surface. 

•  Do not use if the wind velocity is greater than 10 miles per hour.

•  Unit will operate at reduced efficiency below 40°F (5°C).

• 

It is normal for the heater to make hissing sounds at the start. This will decrease as the heater warms up.

• 

Keep sprinklers and other water sources away from burner and controls.

• 

Always use extreme caution when near the heater. Young children and pets should be supervised carefully 

when they are near the heater. Do not hand clothing or flammable materials on or near the heater. To avoid 

burns or clothing catching on fire, alert both children and adults to the hazards of high temperatures.

• 

Certain materials or items are susceptible to damage due to radiant heat when stored under heater.

• 

Do not alter heater in any manner.

• 

Inspect heater before each use. If a damaged part is detected, do not operate the heater until an original 

Omcan replacement part has been properly installed. Use of unauthorized parts will void warranty and 

create an unsafe condition.

• 

Prior to operating heater, replace any guards or protective devices removed from servicing.

• 

During operation, the surface of the heater of the burner assembly is very hot and should not be touched

•  After shutdown, do not touch burner assembly until heater has completely cooled down (approximately 45 

minutes after use.)

• 

The appliance and its individual shut off valve must be disconnected from the gas supply pipping system 

during any pressure testing. The system should be tested in the pressure in excess of 1/2 psig (3.5kpa).

• 

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off 

valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 

psig (3.5kpa).

•  Always perform a leak test on ga connections whenever heater is serviced. Never use a flame to test for 

leaks. Do not smoke while performing a test leak.

• 

Caution: It is essential to keep the heater’s valve compartment, burners and circulating air passage clean.

Summary of Contents for PH-CN-0014

Page 1: ...Patio Heater Model PH CN 0014 Item 43595 Instruction Manual Revised 04 18 2018 Factory CSA approved Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...14 15 15 16 16 17 18 19 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Re...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...ido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la...

Page 5: ...e wind velocity is greater than 10 miles per hour Unit will operate at reduced efficiency below 40 F 5 C It is normal for the heater to make hissing sounds at the start This will decrease as the heate...

Page 6: ...valves can be quickly identified by their external and internal threads The cylinder must be provided with a shutoff valve termination in an LP gas supply cylinder valve outlet specified as applicabl...

Page 7: ...ss Steel Safety Features 100 Burner Shut Off Heat Range Up to 20 foot diameter Inlet Gas Supply Pressure Maximum 10 5 W C Minimum 7 0 W C Fuel Use propane or butane gas only Gas Supply Pressure 120 PS...

Page 8: ...using the reinforced ring NN M6 x 10 mm bolts DD and 6 small flat washers EE Fasten and cover with the deck ring OO 5 Slide fastening nut G down the post J with the rounded side facing down Next slide...

Page 9: ...0 Remove protective cover from reflector panel A and reflector plate B Note In order to achieve proper alignment of reflector sections it may be necessary to loosen the preassembled bolts prior to ass...

Page 10: ...nder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the standard for cylinders spheres and tubes for transport...

Page 11: ...regulator connection This part is defective and you should contact the customer service department for replacement If NO bubbles appear at any connection the connections are secure NOTE Whenever gas c...

Page 12: ...ight then Push in control knob and turn counterclockwise to PILOT As you are depressing the control knob place long stem lighter into the ignition hole on the emitter screen to light the pilot Repeat...

Page 13: ...ns noted All components are properly assembled intact and operable No alterations have been made All gas connections are secure and do not leak Wind velocity is below 10 mph Unit will operate at reduc...

Page 14: ...ler particles Carbon deposits may create a fire hazard Clean dome and burner screen with warm soapy water if any carbon deposits develop NOTE In a salt air environment such as near an ocean corrosion...

Page 15: ...stay lit Dirt built up around pilot Clean dirt from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and perform leak check Thermocouple is not operating corre...

Page 16: ...an unsafe condition Always allow heater to cool before attempting service Troubleshooting Gas odor with extreme yellow tipping of flame Spiders and insects nest in burner or orifices Clean burner and...

Page 17: ...17 Parts Breakdown Model PH CN 0014 43595...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...