POSITIONING

Ensure that in respect of the unit dimensions, the space around the unit is suitable for both operation and easy 

maintenance. Place the cabinet on a flat and level surface with it’s adjustable legs. If the unit has been placed 

on its side, please keep the machine inactive for 2 hours so the condenser fluid can settle. Do not position 

close to any heat source, explosives or in the path of direct sunlight. Air circulation must be freely maintained 

around the condensing unit. Failure to follow the above will cause damage to the unit and void the warranty.

ELECTRICAL CONNECTION

Check that the supply conforms to the requirements shown on the rating label. The connection must be 

grounded. The supply cable should never be stretched or pinched, keep the cable away from contact with 

liquids or heat sources. In the even of damage it must be replaced by Omcan.

Model

PT-CN-0390

PT-CN-0580-2

PT-CN-0580

Temperature Range

-2 to 8°C / 28.4 to 46.4°F

Max Ambient Temp 

Rating

24°C / 75°F

Electrical

110-120V / 60Hz / 1

Capacity Power

190 W

290 W

Input Power

170 W

210 W

Refrigerant

R290

Consumption

2 kW/h

Capacity

390 L / 13.8 cu.ft.

580 L / 20.5 cu.ft.

580 L / 20.5 cu.ft.

Granite Thickness

1.2” / 30mm

Partition Width

17.1” / 435mm

29.4” / 746mm

17.1” / 435mm

Overall Interior Cabinet 

Width

37.2” / 945mm

61.5” / 1562mm

Dimensions

59.4” x 31.5” x 39.4”

1510 x 800 x 1000mm

79.5” x 31.5” x 39.4”

2020 x 800 x 1000 mm

Packaging Dimensions

64.2” x 36.2” x 40.2”

1630 x 920 x 1020mm

84.3” x 36.2” x 40.2”

2140 x 920 x 1020mm

Weight

478.4 lbs. / 217 kgs.

544.5 lbs. / 247 kgs.

542.3 lbs. / 246 kgs.

Packaging Weight

556 lbs. / 252.2 kgs.

683.4 lbs. / 310 kgs.

681.2 lbs. / 309 kgs.

Item Number

39592

48621

41145

Technical Specifications

Summary of Contents for PT-CN-0390

Page 1: ...Revised 05 10 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Prep Tables Models PT CN 0390 0580 2 0580 Items 39592 48621 41145 Instruction Manual...

Page 2: ...Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registra...

Page 3: ...causados por fugas de agua La garant a por fugas de agua queda anulada si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desag e del aparato no est conectado directamente a...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...ra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os v...

Page 6: ...authorities If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by...

Page 7: ...vers electrical and part failures not improper use Please see https omcan com disclaimer for complete info WARNING The packaging components are classified as normal solid urban waste and can therefore...

Page 8: ...r be stretched or pinched keep the cable away from contact with liquids or heat sources In the even of damage it must be replaced by Omcan Model PT CN 0390 PT CN 0580 2 PT CN 0580 Temperature Range 2...

Page 9: ...arrows to either increase or decrease the temperature as desired confirm the new temperature by pressing SEL STORAGE OF FOODSTUFFS In order to obtain the best possible function of the cabinet it is ne...

Page 10: ...ct from the power supply Unscrew rotate and remove the protective grill Remove the dust on the front surface by using a brush and a vacuum cleaner then reattach the protective grill Place the merchand...

Page 11: ...t The condenser is not blocked with dust The cabinet is not located near heat sources or its condensing unit has uninterrupted air flow The stored foods or other objects do not inhibit the proper clos...

Page 12: ...12 Parts Breakdown Model PT CN 0390 39592...

Page 13: ...r 39592 39 AF212 Down Hinge Left for 39592 8 AD825 Condenser Fan for 39592 24 AF241 Water Box Protector for 39592 40 AF213 Up Hinge Left for 39592 9 AF228 Evaporator for 39592 25 AF242 Clip for 39592...

Page 14: ...14 Parts Breakdown Model PT CN 0580 2 48621...

Page 15: ...8621 24 AF242 Clip for 48621 41 AM482 Bottom Hinge Left for 48621 8 AF228 Evaporator for 48621 25 AM495 Bottom Hinge of Control Panel for 48621 42 AM483 Top Hinge Left for 48621 9 AM486 Compressor Roo...

Page 16: ...16 Parts Breakdown Model PT CN 0580 41145...

Page 17: ...inge for 41145 39 AF212 Down Hinge Left for 41145 8 AD825 Condenser Fan for 41145 24 AF241 Water Box Protector for 41145 40 AF213 Up Hinge Left for 41145 9 AF228 Evaporator for 41145 25 AF242 Clip for...

Page 18: ...18 Electrical Schematics Model PT CN 0390 39592 Model PT CN 0580 2 48621 Model PT CN 0580 41145...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: