7
Installation
IMPORTANT!!!PLEASE READ BEFORE INSTALLATION
• If the unit has recently been transported. Please let unit stand still for a minimum of 24 hours before
plugging it in.
• Make sure that the unit drops down to desired temperature before loading the unit with product.
• Make sure that there is proper ventilation around the unit in the area where it will operate.
• Make sure all accessories are installed(i.e. shelves, shelf clips, casters) before plugging the unit in.
• Please read through the Operation / Owner’s Manual in its entirety.
CABINET LOCATION GUIDELINES
• Install the unit on strong and leveled surfaces.
- Unit may make unpleasant noises if surface is uneven.
- Unit may malfunction if surface is uneven.
• Install the unit in an indoor, well-ventilated area.
- Unit performs more efficiently in a well-ventilated area.
- For best performance, please maintain clearance of 6” on the back of the unit.
- Outdoor use may cause decreased efficiency and damage to the unit.
• Avoid installation in a high humidity and/or dusty area.
- Humidity could cause unit to rust and decrease efficiency of the unit.
- Dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least once a
month with a brush or clean cloth.
- Malfunction due to dirty condenser will void warranty.
• Select a location away from heat and moisture-generating equipment.
- High ambient temperature will cause the compressor to overwork, leading to higher energy bills and
gradual breakdown of the unit.
- Malfunction due to high ambient temperature will void warranty.
ELECTRICAL
Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage
can detrimentally affect the refrigeration unit. All units should be plugged into a grounded and properly-sized
electrical outlet with appropriate overcurrent protection. Please refer to the electrical requirement on the
nameplate of the unit. Please make sure that your unit has its own dedicated outlet. Do not use an extension
cord.
TEMPERATURE CONTROLS
The temperature controls are factory-set to maintain an average temperature of 38°F in refrigeration. To
maintain a different temperature, adjust it on the temperature controller–
see manual of temperature controller.
CAUTION
Setting the temperature control to the coldest setting may cause the evaporator coil to freeze and ice up. This
Summary of Contents for RE-CN-0006-HC
Page 18: ...18 Parts Breakdown Model RE CN 0006 HC 50054 ...
Page 20: ...20 Parts Breakdown Model RE CN 0011 HC 50056 ...
Page 22: ...22 Parts Breakdown Model FR CN 0686 HC 50053 ...
Page 24: ...24 Parts Breakdown Model FR CN 1219 HC 50055 ...
Page 26: ...26 Model RE CN 0006 HC 50054 Model RE CN 0011 HC 50056 Electrical Schematics ...
Page 27: ...27 Electrical Schematics Model FR CN 0686 HC 50053 Model FR CN 1219 HC 50055 ...