Model

RE-CN-0021-G-HC

RE-CN-0041-G-HC

RE-CN-0067-G-HC

Net Volume

650 L / 23 cu.ft.

1321 L / 47 cu.ft.

2040 L / 72 cu.ft.

Temperature Range

0.5 - 5°C / 33 - 41°F

Max Ambient Temp 

Rating

32°C / 90°F

Horsepower

1/5 HP

1/4+ HP

3/4 HP

Electrical

110V / 60Hz / 1

Current

2.6A

3.8A

9A

Refrigerant

R290

Isolation Material

Cyclopentane

Cooling System

Ventilated

Number of Doors

1

2

3

Number of Shelves

3

6

9

Shelf Capacity

59.5 lbs. / 27 kgs.

Exterior Dimensions

29” x 32.3” x 82.5”

736 x 818 x 2095mm

54” x 32.3” x 82.5”

1371 x 818 x 2095mm

81” x 32.3” x 82.5”

2054 x 818 x 2095mm

Interior Dimensions

24” x 27” x 53.5”

620 x 688 x 1360mm

49.4” x 27” x 60.2”

1255 x 688 x 1530mm

76” x 27” x 60”

1938 x 688 x 1530mm

Packaging Dimensions

30.4” x 35” x 83.5”

770 x 890 x 2120mm

56.8” x 35” x 83.5”

1440 x 890 x 2120mm

83.5” x 35” x 83.5”

2120 x 890 x 2120mm

Weight

282 lbs. / 128 kgs.

447 lbs. / 203 kgs.

616 lbs. / 280 kgs.

Packaging Weight

337 lbs. / 153 kgs.

513 lbs. / 233 kgs.

704 lbs. / 320 kgs.

Item Number

51024

51026

51028

Safety and Warranty

In any case, for suitable recycling, we suggest disposing of the products separately (differentiated 

waste) according to the current norms.

DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Summary of Contents for RE-CN-0021-G-HC

Page 1: ...d 06 21 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Reach In Glass Door Coolers Models RE CN 0021 G HC 0041 G HC 0067 G HC Items 51024 51026 51028 Instruction...

Page 2: ...ction Disclaimer General Information Safety and Warranty Technical Specifications Installation Maintenance Troubleshooting Controller Instructions Parts Breakdown Electrical Schematics Notes Warranty...

Page 3: ...S NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS75 FAND55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECT...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...sando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL PAQUETE A SU...

Page 6: ...ize personal injury do not hang on the doors Do not store any flammable and explosive gas or liquids inside the unit Do not attempt to alter or tamper with the electrical cord RESIDENTIAL USERS Vendor...

Page 7: ...54 x 32 3 x 82 5 1371 x 818 x 2095mm 81 x 32 3 x 82 5 2054 x 818 x 2095mm Interior Dimensions 24 x 27 x 53 5 620 x 688 x 1360mm 49 4 x 27 x 60 2 1255 x 688 x 1530mm 76 x 27 x 60 1938 x 688 x 1530mm Pa...

Page 8: ...nction Clean the condenser at least once a month with a brush or clean cloth Select a location away from heat and moisture generating equipment high ambient temperature will cause the compressor to ov...

Page 9: ...ANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless ste...

Page 10: ...loose part s Tubing vibration Ensure tubing is free from contact with other tubing or components Condensing unit runs for long periods of time Excessive amount of warm product Placed in cabinet Allow...

Page 11: ...rm product Placed in cabinet Allow adequate time for product to cool down Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Dirty condenser coil Clean the condenser coil Prol...

Page 12: ...ntrol functions see Table 1 while the 3 buttons can be used to activate deactivate some of the functions see Table 2 LED s and Associated Functions Table 1 Icon Function Normal Operation Start Up ON O...

Page 13: ...g after a few moments Increase or decrease the value using UP or DOWN Press SET to confirm the new value Switching the device ON OFF Press UP for more than 3 sec The control and defrost algorithms are...

Page 14: ...and finally SET to confirm the changes returning to the parameter menu To save all the new values and exit the parameter menu press SET for 3 s To exit the menu without saving the changed values exit...

Page 15: ...15 Parts Breakdown Model RE CN 0021 G HC 51024...

Page 16: ...bling Panel for 51024 10 AA805 Power Cord for 51024 28 AG464 Control Panel Fixer for 51024 49 AF041 Right Track for Assembling Panel for 51024 11 AG452 Compressor Unit Installation Board for 51024 29...

Page 17: ...17 Parts Breakdown Model RE CN 0041 G HC 51026...

Page 18: ...allation Board for 51026 29 AG463 Back Grill Fixer for 51026 51 AF041 Right Track for Assembling Panel for 51026 10 AG555 Condenser for 51026 30 AG464 Control Panel Fixer for 51026 52 AG551 Evaporator...

Page 19: ...19 Parts Breakdown Model RE CN 0067 G HC 51028...

Page 20: ...ng Panel for 51028 10 AG572 Compressor Unit Installation Board for 51028 31 AG462 Baffle of Suction Line for 51028 55 AF041 Right Track for Assembling Panel for 51028 11 AG555 Condenser for 51028 32 A...

Page 21: ...21 Electrical Schematics Model RE CN 0021 G HC 51024...

Page 22: ...22 Electrical Schematics Model RE CN 0041 G HC 51026...

Page 23: ...23 Electrical Schematics Model RE CN 0067 G HC 51028...

Page 24: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 25: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 26: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 27: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 28: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: