12
Troubleshooting
Cabinet Temperature Is too warm. Thermostat set too warm.
Set thermostat to lower
Temperature.
Blocking air flow.
Re-arrange product to allow for
Proper air flow. Make sure there
Is at least four inches of clearance
from evaporator.
Excessive amount of warm product
Placed in cabinet.
Allow adequate time for product to
cool down.
Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit
breaker.
Dirty condenser coil.
Clean the condenser coil.
Prolonged door opening or door
ajar.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Evaporator coil iced over.
Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that door
gasket(s) are sealing properly.