9
Installation
•
Lamps must be replaced by identical lamps only.
ELECTRICAL INSTRUCTIONS
•
Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter. If
anything less than 100% of the rated voltage for operation is noted, correct immediately.
• All units are equipped with a service cord, and must be powered at proper operating voltage at all times.
Refer to cabinet data plate for this voltage.
WARNING:
Compressor warranties are void if compressor burns out due to low voltage.
WARNING:
Power supply cord ground should not be removed!
WARNING:
Do not use electrical appliances inside the food storage compartments of the appliances unless
they are of the type recommended by the manufacturer.
NOTE:
To reference wiring diagram, remove front louvered grill,wiring diagram is positioned on the inside
cabinet wall.
DRAWER REMOVAL & INSTALLATION
REMOVAL
1. Open drawer completely. Roller clips will be in the down position.
2. While holding the sides of the drawer, use your hands to lift side track of drawer.