6
Installation
INSTALLATION AND STORAGE
1.
Keep the unit vertical when carrying the unit, the angle to the horizontal line should not be over 50°,
otherwise it will damage the compressor and affect normal operation of the unit.
2.
The unit should be place on a solid and firm ground, take away the bottom pack to lower the shock and
noise.
3. Leave at least 20 cm of distance between the back of the unit and the wall for ventilation and leave a space
with an open angle of 160 ° for the door.
4. Keep the unit away from heat sources and avoiding direct sunlight.
5.
Never place the unit on a location where water can reach or with high moisture. Splashed water and dirt
should be wiped off in time by using a soft cloth.
Technical Specifications
Model
RS-CN-0021-B
RS-CN-0040-B
RS-CN-0052-B
RS-CN-0080-B
Capacity
21 L / 0.74 cu. ft.
40 L / 1.41 cu. ft.
52 L / 1.83 cu. ft.
80 L / 2.82 cu. ft.
Power
76W
92W
Power Consumption
0.6 kW per hour
0.7 kW per hour
1 kW per hour
Temperature Range
0 - 10°C / 32 - 50°F
Refrigerant
R600a / 18g
Maximum Ambient
Temperature
38°C / 100.4°F
Defrosting
Yes
Temperature
Controller
Mechanical
Number of Shelves
2
3
Shelf Material
ABS
Shelf Capacity
33 lbs. / 15 kgs.
Shelf Dimensions
9.8” x 10.2”
250 x 260mm
12” x 10”
305 x 255mm
13” x 10.6”
330 x 270mm
13.8” x 11”
350 x 280mm
Electrical
110V / 60Hz
Interior Dimensions
9.8” x 10.2” x 14.3”
250 x 260 x 363mm
12” x 10” x 17.7”
305 x 255 x 450mm
13” x 10.6” x 19.7”
330 x 270 x 500mm
13.8” x 11” x 24.8”
350 x 280 x 630mm
Exterior Dimensions
13” x 16.3” x 24”
330 x 415 x 610mm
15.7” x 16.3” x 28.9”
330 x 415 x 610mm
16.5” x 18.1” x 31.2”
420 x 460 x 793mm
18.2” x 18.5” x 36.7”
463 x 470 x 933mm
Weight
35 lbs. / 16 kgs.
44 lbs. / 20 kgs.
50.7 lbs. / 23 kgs.
63.9 lbs. / 29 kgs.
Item Number
44575
44528
44529
44530