background image

8

Troubleshooting

Trouble

Causes

Solutions

Strange noise under the 

bottom shelf.

Fan blade broken.

Power off and fix the blade.

Non-refrigerating in spite of 

normal operation.

Unit off.

Power on.

Melting process.

Stop melting.

Refrigerant leaking.

Patch the leak and refill refrigerant.

Unit failure.

Call Omcan.

Weak air from air curtain, 

and higher cabinet 

temperature.

Evaporator blocked by frost.

Increase melting frequency.

Inside fan damaged.

Replace the fan.

Too low point of temperature 

controller.

Adjust the set point.

Vent blocked by storage.

Remove the storage.

Normal air curtain, but 

higher cabinet temperature.

Insufficient refrigerant.

Refill the refrigerant.

Too high set point of temperature 

controllers.

Adjust the set point for the 

temperature controller.

The wind curtain disturbed by strong 

air flow.

Removing the disturbing factors.

Ambient temperature or humidity 

beyond standards.

Improve the conditions.

Melting water overflows.

Heating pipe for melting water 

damaged.

Replace the heating pipe.

Water level controller failure.

Replace the water level controller.

Ambient temperature or humidity 

beyond standards.

Improve the conditions.

Maintenance

1.  Cabinet Cleaning: 

a. The product should be maintained and cleaned periodically with power supply disconnected. In cleaning, 

please use mild-rinsing water or non-corrosive products. Do not wash directly with water faucet. 

b. Clean outside of unit using a soft cloth with neutral detergent, and dry with a separate soft cloth. 

c. Clean inside racks by removing them from the unit and clean with water.

2.  When shutting down unit for a long period of time, take out all food and unplug wall socket. Clean inside 

and outside thoroughly, and keep door open to sufficiently dry.

3.  As glass breaks easily, keep far away from children.

4.  Frequently observe the operation of the product. In case of any abnormal noise or smell, cut off the power 

supply immediately and call professionals. Do not restart the product before source of trouble is found.

5.  We will not be responsible for any accidents acquired through failure to follow previous notices.

Summary of Contents for RS-CN-0700

Page 1: ...Revised 09 12 2017 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcases Models RS CN 0530 0700 1050 Items 43459 41469 43460 Instruction Manual...

Page 2: ...Table of Contents Section General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Model RS C...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...nspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en...

Page 5: ...ground No shared power outlets Refrigerator cable should never share the power outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be u...

Page 6: ...gs 55 lbs 30 kgs 66 lbs 50 kgs 110 lbs Temperature 2 10 C 35 6 50 F Ambient Temperature RH 27 C 80 6 F 70 Refrigerant Injection g R404a 960 R404a 1250 R404a 1300 Type of Climate 3 6 3 Rated Current 11...

Page 7: ...the LED flashes 5 Defrost LED During defrosting the LED is on When it stops defrosting the LED is off During the delay of defrost the LED flashed CAUTION Never block the air outlet and suction to keep...

Page 8: ...g pipe for melting water damaged Replace the heating pipe Water level controller failure Replace the water level controller Ambient temperature or humidity beyond standards Improve the conditions Main...

Page 9: ...are not problems The murmur of water is heard when the refrigerator is working It is a normal occurrence as the coolant is circulating in the system When the weather is damp condensation might be foun...

Page 10: ...10 Parts Breakdown Model RS CN 0530 43459...

Page 11: ...uard in Base for RTS530L 15 60632 Right Support Pillar of Shelf for RTS530L 45 60662 Lower Front Waling for RTS530L 77 60603 Foam of Base Plate for RTS530L 16 60633 Foam of Right Board for RTS530L 46...

Page 12: ...12 Model RS CN 0700 41469 Parts Breakdown...

Page 13: ...Bottom Strip for RTS 700L 28 70147 Shelf Support Pole for RTS 700L 48 70109 Fan for RTS 700L 10 70128 Louver Components for RTS 700L 29 70148 Power Cord for RTS 700L 49 70110 Flange for RTS 700L 11 70...

Page 14: ...14 Parts Breakdown Model RS CN 1050 43460...

Page 15: ...for RTS1050L 79 60605 Evaporator Cover for RTS1050L 16 60701 Lampshade for RTS1050L 48 60723 Condenser Right Windshield for RTS1050L 80 60681 Right Board of Evaporator Cover for RTS1050L 17 60630 Hol...

Page 16: ...16 Electrical Schematics Model RS CN 0530 43459...

Page 17: ...17 Electrical Schematics Model RS CN 0700 41469...

Page 18: ...18 Electrical Schematics Model RS CN 1050 43460...

Page 19: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: