background image

Use and maintenance manual

complete of 

EC

 conformity declaration.

LIFTING BRACKET

VDI3366

Item code: 

B01.10-B01.12

San Maurizio C.se - 11/07/2018

www.omcr.it

Via Quarantelli 8 -10077 - S. Maurizio C.se - Italy

T

 +39 011 996 46 11 - 

F

 +39 011 996 46 46

C.F./P.IVA 

07677130010

info@omcr.it - www.omcr.it

Summary of Contents for VDI3366

Page 1: ...conformity declaration LIFTING BRACKET VDI3366 Item code B01 10 B01 12 San Maurizio C se 11 07 2018 www omcr it Via Quarantelli 8 10077 S Maurizio C se Italy T 39 011 996 46 11 F 39 011 996 46 46 C F...

Page 2: ...l B01 10 B01 12 San Maurizio C se 11 07 2018 www omcr it 1 Risks valuation 2 Symbols and warnings classification 3 Use 4 Handling and storage 5 Maintenance 6 EC conformity declaration pag 3 pag 3 pag...

Page 3: ...materials have been subjected to tensile stress test according to UNI EN 10002 Calculations and risk assessments have been made according to VW AUDI BMW MERCEDES BENZ VDI3366 norms An improper or opp...

Page 4: ...executed by qualified and instructed worker the lifting handling or turnover officers must use individual guard equipment WARNING 3 1 Before each lifting handling overturning officers have to choose t...

Page 5: ...escriptions included in this manual may cause the accidental fall of the load 3 2 2 The die overturning is not allowed see Pic 1 WARNING Pic 1 G Die load center Minimum rope angle from vertical 1 Maxi...

Page 6: ...any defect or deformation to make it unsafe in case eliminate immediately the defective parts WARNING 3 4 At the moment of the use check the correct screws clamping and the use of screws with the requ...

Page 7: ...rried out see Pic 3 WARNING 3 6 The missing respect of the prescriptions included in this manual may cause the accidental fall of the load WARNING OMCR CODE H mm B01 10 016 B01 12 016 6 B01 10 020 B01...

Page 8: ...the ropes chains are not hooked to the die corners WARNING 3 9 Don t stand or transit nearby the load during lifting or handling operations see Pic 6 In case of accidental release of the load there ma...

Page 9: ...dirt on the contact surface between the lifting bracket and the mold holder plate may compromise the correct functioning of the lifting bracket WARNING 4 2 1 5 MAINTENANCE 5 1 Each 6 months make visu...

Page 10: ...ponsible of the technical file acting in OMCR Via Quarantelli 8 10077 San Maurizio C se These procedures have been exactly issued to allow OMCR mark with EC symbol to ensure that these products are in...

Reviews: