background image

 
 

 

Installation and operating 

manual 

 

Please read the following instructions carefully before installing the product. 
Trouble free and safe operating of the product can only be guaranteed if 
recommendations and conditions stated in this manual are respected. 

3403196 

 Omega_Air_User_Manual_Condensate_Drain_AOK_13PA_19122019 

 

AOK 13PA 

(Condensate drain) 

 

 

 

 

Summary of Contents for AOK 13PA

Page 1: ...s carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manual are respected 3403196 Omega_Air_User_Manual_Condensate_Drain_AOK_13PA_19122019 AOK 13PA Condensate drain ...

Page 2: ... 2 Components Parts 1 M6 screws 2 Drain housing 3 Test lever 4 Floater holder 5 Sealing nipple 6 Orifice sealing 7 M6 Nuts 8 Drain housing 9 Floater 10 Housing sealing 11 Connector nipple optional 12 Plug with O ring 1 3 9 1 0 8 7 2 6 11 4 5 1 ...

Page 3: ...ng NBR Operation pressure range 0 13 bar 0 188 psi Minimum recommended operating pressure 1 5bar g 21 8 psi Drain capacity 7 bar 101 psi 167 l h 0 1 scfm Drain capacity 13 bar 188 psi 226 l h 0 13 scfm Operating temperature range 1 5 50 C 35 122 F Operating media Condensate air water oil Non aggressive Inlet connection G Outlet connection G Reservoir volume 0 4 l Mass 0 5 kg Dimensions A x B x C m...

Page 4: ...perating pressure or operating temperature range see data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Use the device for the appropriate purpose only AOK 13PA condensate drain is intended exclusively for use in draining condensate from compressed air system air compressors air receivers air dryers and filters Any others form o...

Page 5: ...e drain reservoir Increasing condensate level rises the floater When the condensate level is high enough the floater unblocks the discharge orifice and the condensate is purged out through G output connection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss By tightening the test lever we lift the float manually and simulate the op...

Page 6: ... plug the horizontal second connection When used this way it is recommended to used appropriate nipple to assure a constant flow of a condensate to a reservoir of the drain Recommended use of nipple Nipple prevents creation of air bubbles which blocks the path for condensate to flow in the reservoir Air trapped in the reservoir of a drain can pass back to a pressure equipment through intended pipe...

Page 7: ...ded that waste condensate from discharge port is connected to water treatment application such as water oil separator to protect the environment from pollution and to comply with environmental laws Installation procedure 1 Assure there is no pressure in the system 2 Visually check the drain that there is no damage that would impact drains operation 3 Choose appropriate way of installation horizont...

Page 8: ...ose and there should be no more air leakage YEARLY Dismantle the drain and clean all components Do not use solvents to clean rubber components Service It is recommended to clean reservoir at least once a year It is also recommended to change sealings Sealing elements are subject to wear which depends on various operating parameters such as pressure temperature dirt content etc Attention Prior main...

Page 9: ...commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not operated within the permissible technical parameters Unauthorized constructional changes were made to the unit or if the unit has been opened disassembled by an unauthorized person ...

Page 10: ...ption Condensate drain Serial Number see name plate Is in conformity with the following directives Pressure Equipment Directive PED 2014 68 EU Fluid group 2 AOK 13PA Not required A Dobnikar Technical manager Date of issue 19 12 2019 Our quality management system is certified by BUREAU VERITAS in conformity with ISO 9001 2015 Reg number 200285 ...

Page 11: ...AOK 13PA Installation and operating manual 11 ...

Page 12: ...AOK 13PA Installation and operating manual 12 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia T 386 0 1 200 68 00 F 386 0 1 200 68 50 info omega air si ...

Reviews: