25
EN
MAINTENANCE
• Correct maintenance is crucial to achieve maximum efficiency of your compressor, and to lengthen its operating life.
• It is also important to comply with the maintenance intervals recommended, but it must be remembered that such intervals
are suggested by the manufacturer in the event that the environmental conditions of use of the compressor are optimal (see
“Installation” chapter).
• The maintenance intervals can therefore be reduced depending on the environmental conditions in which the compressor
operates.
• The oil used is FSN Original Oil, the use of a different oil does not guarantee perfect efficiency and compliance with the
maintenance intervals.
• The maintenance operations described in the table below and on the following pages must be carried out by authorised
staff.
Maintenance table
To verify correct machine operation, perform the followng checks
after the first 100 hours of work
:
1) Check the oil level
: top up with the same type of oil if necessary.
2) Check for proper screw tightening
:
in particular the power electric connection screws.
3)
Visually check that all
fittings seal properly.
4)
Check the
hours of work
and the
type of service selected
5)
Check
room temperature
.
BEFORE MAINTAINING THE MACHINE ALWAYS PERFORM THE FOLLOWING:
√
Press the machine automatic stop button
(do not use the emergency button).
√
Power the machine off by means of the wall outer switch.
√
Close the line cock.
√
Make sure that no compressed air is inside the oil separator tank.
√
Remove fairing and/ or panels.
Type of maintenance
Maintenance schedule
work hours
o at least
(when MINERAL
OIL is used)
(when SYNTHETIC
OIL is used)
Drain condensate from air tank (if present)
50
50
weekly
Drain condensate from the oil tank
50
50
weekly
Clean cabinet pre-filter panel
50
50
weekly
Oil check and top up
500
500
once per month
Clean intake air filter cartridge
500
500
-
Check and clean radiator
1000
1000
once a year
Replace primary intake air filter cartridge
2000
2000
once a year
Replace secondary intake air filter cartridge
4000
4000
once a year
Replace oil filter
2000
4000
once a year
Replace oil separator filter
2000
4000
once a year
Replace oil
2000
4000
once a year
Replace scavenge non return valve
4000
4000
once a year
Replace cabinet pre-filter
4000
4000
once a year
Condensate drainage filter cleaning
4000
4000
once a year
Intake valve service
8000
8000
Minimum pressure valve overhaul
8000
8000
Thermostatic valve service
8000
8000
Replace joint flexible
8000
8000
Replacing solenoid valves *
8000
8000
Replace flexible hoses
8000
8000
Air-end overhaul/ replacement
24000
24000
Refer to the motor manual and/or to the motor data plate for electric motor bearing maintenance.
* The second solenoid valve is on the condensation separator (for models fitted with it).
NOBEL DV 30-37 CSA - Cod.197EE0612ML - Rev.2 09/2019