5-6 PostView
NetScan User’s Manual
Menu Items
File
Open
Opens a data file created by the data acquisition program. PostView automatically
detects whether the file contains ASCII or binary data.
Prints the present PostView window.
Setup
Accesses Display Configuration Setup dialog box, allowing you to edit the display
configuration.
Wizard
Accesses the Chart Setup Wizard.
Exit
Exits the File menu.
Go To
Percentage
(Ctrl+P)
Automatically scrolls the waveform such that the displayed waveform begins at the
specified percentage.
Scan Number
(Ctrl+S)
Automatically scrolls the waveform such that the displayed waveform begins at the
specified scan number.
Time
(Ctrl+m)
Automatically scrolls the waveform such that the displayed waveform begins at the
specified time.
Trigger Point
(Ctrl+T)
Automatically scrolls the waveform such that the displayed waveform begins at the trigger
point (t = 0).
Note: In PostView Version 3.0 – If there is a Pre-trigger, then Pre-trigger and Post-trigger times (in seconds) are
displayed in the Go To menu’s dialog box.
Options
Zoom Graph Out
Allows more of a chart(s) to be seen by decreasing the dimensions.
Zoom Graph In
Zooms in on a chart(s), providing more detail to a smaller area of the chart(s).
Zoom Chart
Zoom Chart causes PostView to display one chart only. For example, if you were viewing
3 charts and desired to get a better view of Chart 2, you could use Zoom to view Chart 2
using the full chart viewing area, as compared to using one third of the area. The zoom
feature can also be invoked by double-clicking in the chart region of the chart for which
you want to apply the zoom.
Once you have zoomed in on a chart, the pull-down menu Zoom option is replaced by a
Restore option. Selecting Restore from the menu will return the main window to its
previous multiple chart viewing status. The restore feature can also be invoked by again
double-clicking in the chart region.
Absolute time
(Ctrl+A)
Places the timebase in a 24-hour absolute time format. For example:
25.2 seconds after 3:08 p.m. would appear as 15:08:25.2.
(Also see PostView Timebase, page -15.)
Relative time
(Ctrl+R)
Places the timebase in a relative time format, typically having 00:00:00.0 as the start time
and having other times represented as hours, minutes, seconds and tenths which have
elapsed since the start time. (Also see PostView Timebase, page -15.)
Autoscale Current
Channel
For the currently selected channel, automatically generates a scale, in contrast to
manually assigning the scale.
Autoscale All
Channels
Automatically generates a scale for each channel in every chart of the selected group.
Show Grid
(Ctrl+G)
Allows grids to be turned off and on for all visible graphs. When a check appears in front
of an item, its indicator is on or visible.
Show Markers
(Ctrl+K)
Allows markers to be turned off and on for all visible graphs. When a check appears in
front of an item, its indicator is on or visible.
Data Commentary
(Ctrl+C)
This function is hidden unless a comment has been added to the data header file. If such
a comment has been entered, then Data Commentary will be visible, allowing you to
display the comment in a message box. The comment feature is supported by certain
acquisition software, and can only be used by PostView versions 3.3 or greater. For
ChartView users: note that commentary can be entered in ChartView’s Setup/Data
Destination dialog box, providing the commentary feature is enabled. To enable the
feature in ChartView, start with the View pull-down menu and navigate as follows:
View
⇒
Options
⇒
Acquisition
⇒
(
3
) Enable PostView Comment (refer to the software
chapter, if needed.)
Help
Contents
The initial PostView help screen provides an overview and listing of the help file contents.
A single topic can be selected for quick access to help information.
Search
Type a word or select one from the Show Topics list for quick access to help information.
Help on Help
Provides instructions on how to use a Windows Help system.
About
Provides PostView’s version number.
Summary of Contents for OMB-NETSCAN 1500
Page 6: ...iv NetScan User s Manual...
Page 18: ...1 12 Configuring and Starting NetScan NetScan User s Manual Notes...
Page 38: ...3 8 General Information and Specifications NetScan User s Manual Notes...
Page 82: ...4 44 ChartView Software Reference NetScan User s Manual Notes...
Page 118: ...6 20 Calibration NetScan User s Manual...
Page 140: ...A ii NetScan User s Manual...
Page 192: ...API Command Reference Appendix A A 52 NetScan User s Manual Notes...
Page 237: ...Appendix D Registers Data Formats Queries NetScan User s Manual D 13...
Page 244: ...NetScan Program Examples Appendix E E 2 NetScan User s Manual...
Page 248: ...ASCII Code Summary Appendix F F 4 NetScan User s Manual Notes...
Page 250: ...NetScan Error Messages Appendix G G 2 NetScan User s Manual Notes...
Page 252: ...Abbreviations Appendix H H 2 NetScan User s Manual Notes...
Page 254: ...NetScan User s Manual...