background image

OMEGA SA  

WORLD SERVICE ORGANIZATION  

GT-19-C-013-E - C - 1538

/8

Fig. 2.0

2.0 Electrical tests

Speci

fi

 c information for calibre 1538

Adjustment of the operation by inhibition. The operation can 

only be measured with a device used to measure intervals 

of 60 seconds or multiples of 60 seconds. The rate must be 

measured with ambient temperature between 20°C and 

30°C.

Pos. Setting of apparatus

Measurement

Test

Remarks

1

2 V

(Ri 

 10 k

Ω

 / V)

1,55 V

Battery voltage

Measured with battery

2

1 V

(Ri 

 10 k

Ω

 / V)

For Witschi Q 6000: 
the motor LED lights up 
at each impulse.

Impulses per minute at 
the integrated circuit 
output 1 per second.

Measured with checked battery.

3

10 

μ

A

1,20 

μ

A

Movement
consumption

Measured without battery, 
external supply, 1.55 V

Jump of four steps every 
four seconds until supply 
voltage < 1,30 V

EOL. Consumption 
higher than normal.

Measurement without battery, 
with supply voltage < 1.40 V, 
EOL function after 

~ 2 minutes.

0,5 

μ

A

Operation of the time setting 
stem switch in position 3

Measured without battery, 
external supply, 1.55 V.

2 V

 1,30 V

Bring the

  R/T 

point and track 

  –  . 

Control of motor with 8 steps/
sec at 1.55 V and 32 steps/sec 
under voltage 

 1,30 V (EOL).

Lower limit for operating voltage.

Measured without battery, 
variable external supply, starting 
with 1.55V, continually reduce 
voltage until movement stops.

4

• 10 k

Ω

1,3 - 1,8 k

Ω

Coil continuity

Measured without battery.

5

200 

μ

A

110 - 155 

μ

A

Coil isulation

• 

Ohmmeters with measuring voltage greater than 0.40V inappropriate ; recommended voltage 0.20V.

    Ambient  temperature 20°C.

Summary of Contents for 1538

Page 1: ...nd display hours and minutes and seconds date Time zone Stepper servo motor sixty impulses per minute inhibition EOL Technical Guide TG 19 C 013 E C Prod by pelrom Date 24 10 2008 3 Modifications see...

Page 2: ...odifications on version D 3 Information on the battery Movement exchange is recommended Tools 4 Specific information for Calibre 1538 7 8 Hand fitting height Runners for hand setting and hand setting...

Page 3: ...seconds hand jump in relation to the dial markers including a reduction of the wheel engagement play Interchangeability New and old wheel executions must not be mixed there is a serious risk of blocki...

Page 4: ...ic tweezers 502 310 0051 Major points Information on the battery The used battery depends always on the case reference Ref 1449936 1 55 V Low Drain 9 50 mm H 1 60 mm Renata 373 Vartachron V373 UCAR En...

Page 5: ...E C 1538 5 Differences between version 1538A 1538B 1538C and 1538D H3C AH6 AH6 H3D AH6 H3D AH6 RoHS version Calibre 1538C 1538D H3C H 3 S F 5 H 3 S F 5 Non RoHS version Calibre 1538A 1538B Difference...

Page 6: ...Version Reference 1538A 72215381010600 30 027 30 012 Kit 7221530D9999 1538A 1538B 1538B 1538C 1538C 1538D 1538D 7221530D9999 Battery insulator Version Reference 1538A 72214302065100 1538B 1538C 1538D...

Page 7: ...height H3 and version D H3D Specific information for calibre 1538 Fig 1 0 Description Movement holder for hand setting No of runners for hand setting Minimum force N Maximum force N Support jewel Hou...

Page 8: ...Movement consumption Measured without battery external supply 1 55 V Jump of four steps every four seconds until supply voltage 1 30 V EOL Consumption higher than normal Measurement without battery w...

Page 9: ...y pelrom Date of second edition 22 01 2008 Version B rendav Date of last edition 24 10 2008 Version C Modifications of Technical Guide version B Old version A New version B Additional Kit second wheel...

Reviews: