Affichage heures, minutes et secondes
Système de chronographe
5.0 Chronograph System Operation
5. Whilst holding the reset down, turn the eccentric until the
chronograph hand can be blocked (under tension). Then
tighten the eccentric screw.
6. Check the freedom of the hour counter (~1
°
to 5°). If not
OK, start again at point 4.
7. Check that the minute counter is blocked
If OK (no play): move to point 9.
If not OK (free): move the hammer pean aside gently
using a screwdriver. This adjustement takes place in the
START position.
Reset and check that there is no freedom in the minute
counter.
8. Carry out a START-STOP and then reset to zero. Then
check again from point 3.
9. Oil the eccentric pivoting lightly and oil the module
according to the drawing on page 16.
Hour, minute and second display
Chronograph System