15
MENU ITEMS
DISC LVL: Discrimination Level
Discrimination allows you to eliminate metal objects from detection. It is
adjustable from 0 to 80. A discrimination setting of zero is not the same as All
Metal. Discrimination incurs some loss of sensitivity to small and deep objects.
As you adjust the discrimination level, a number will appear in the center of the
LCD. All targets that report a number LOWER than the set discrimination level
will not report a sound or display activity. They have been eliminated from
detection. Note also that target category identifiers will start disappearing from
the top of the LCD screen as you increase the discrimination level. When a
target icon disappears, it means the whole category has been eliminated from
detection. Lowering the DISC LVL setting will make the target category
identifiers return to the screen, even if they are partially eliminated by the
numerical setting.
Access
: Press and release the MENU/Quick-Switch button until DISC LVL menu
item becomes active. Then use and
to adjust the discrimination level.
NOTCH: Selective Target Inclusion or Exclusion
a. The purpose of the NOTCH function is to change the detection status of
a target category and it functions only in DISCRIMINATION Mode.
• If a category was not eliminated from detection, then notching that category
will eliminate it from detection and the category icon will disappear.
• If a category was eliminated from detection (category’s icon not
illuminated), then notching the category will return the category to an
active state and the icon will reappear.
b. The following target categories can be notched in or out:
Foil, Nickel, P-Tab, S-Cap, Zinc, Dime, Qtr. After the Qtr category,
pressing NOTCH will exit the NOTCH function.
c. To select a category for notching, press NOTCH until the desired category
identifier flashes. After a few seconds, the flashing will time out and the
current target category will be notched.
d. Practice pressing NOTCH a few times and its function will become obvious.
The NOTCH feature is not available in ALL METAL Mode.
Access:
Press and release
until NOTCH menu item becomes active.
Then use and
to select desired target category. Repeat the operation to
notch additional categories.
VOLUME
The audio response is limited by the volume setting and it applies to all of the
detector settings in all modes including user interface sounds and alarms. In
addition to target volume it affects PINPOINT, Overload alarm, Ground Grab
over metal alarm and all keypad button “beeps”. It does NOT affect the
sensitivity of the detector. The adjustable range is from 0 to 10.
Access
: Press and release
until VOLUME menu item is activated. Use
and
to modify the audio volume.