5. starting and stopping the engine
Starting the engine
1.
Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected.
2.
Turn the fuel valve lever to the ON position.
3.
Turn the choke rod to the CLOSED position.
4.
Move the engine switch to the ON position.
5.
Pull the starter grip lightly until resistance is felt, then pull briskly.
6.
As the engine warms up, slowly push the choke rod to the OPEN position.
Stopping the engine in an emergency:
To stop the generator in an emergency, turn the engine switch to the OFF position.
In normal use:
1.
Turn the AC circuit breaker to the OFF position.
2.
Turn the engine switch to the OFF position.
3.
Turn the fuel valve lever to the OFF position.
Always do as the following so as to keep the generator in a sound condition:
Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter or
housing.
notice
1.
Always connect the generator to the earth or the Recrea
-
tional vehicles to prevent misusing with wire.
Don’t move the earth wire during normal maintenance or
repair.
warning
2.
If the generator is to supply tow or above loads with
power supply, be sure to connect them one with higher
start current first.
6. service