background image

4.5.11  System

This page provides various options to reboot, restore defaults, upgrade firmware and
download/upload configuration for the iServer. Fields are described below.

Figure 4.22  iServer SYSTEM Page

Reboot – 

Clicking on OK button will reboot the iServer.

After rebooting, please wait 15 seconds before reconnecting.

Defaults – 

Clicking on OK button will reset the iServer to factory default settings.

After 

Defaults

, you need to reboot.

Upgrade –

Before proceeding with the firmware upgrade, enter the name of the file

you plan to use, click on 

Check File Name

button. 

If OK, a new screen will appear and you can then browse to the actual upgrade
firmware file “

iSeries_EIT_x.bin

” and click on the 

Upload

button. 

After the file has upgraded the iServer will automatically reboot and load the new
firmware, you will be returned to the Welcome page.

Before upgrading, it is recommended to save the configuration 

Download

Config

.

After upgrade load 

Defaults

. IP default is 

192.168.1.200

.

It is recommended to reboot after loading 

Defaults.

If you do not reboot the unit will not load the configurations.

After connecting to the IP via the web browser, upload the saved
configuration file, 

Upload Config

.

36

Summary of Contents for C4EIT

Page 1: ...ide omega com e mail info omega com iSeries info omega com specs iseries For latest product manuals omegamanual info Shop on line at Embedded Ethernet for iSeries Monitor Controller C4EIT EIT RoHS 2 C...

Page 2: ......

Page 3: ...Address 9 3 6 TCP Port Socket Number 10 Part 4 Operations 11 4 1 Serial Interface Configuration Communication Protocol 11 4 2 Command Structure 11 4 3 Command Formats 11 4 4 Default IP Address 13 4 5...

Page 4: ...ddress 44 Appendix C IP Netmask 45 Appendix D ASCII Chart 46 ASCII Chart Control Codes 47 Appendix E iConnect Software 48 Appendix F HTTPget Program 50 Appendix G ARP Program 52 Appendix H Telnet Setu...

Page 5: ...erver DEVICE SETUP Page EIT 32 Figure 4 18 iServer DEVICE PARAMETERS Page EIT 33 Figure 4 19 iServer READINGS Page C4EIT 34 Figure 4 20 iServer DEVICE SETPOINTS Page 34 Figure 4 21 iServer TERMINAL Pa...

Page 6: ...Annunciators 5 Table 2 2 Data Transmission Characteristics RS485 5 Table 2 3 Half Duplex Hookup 6 Table 4 1 Command Prefix Letters 11 Table 4 2 Command Formats 11 Table K 1 iLog Excel Applications 66...

Page 7: ...ng slip and verify that you have received everything listed Inspect the container and equipment for signs of damage as soon as you receive the shipment Note any evidence of rough handling in transit I...

Page 8: ...on The switch shall not be incorporated in the main supply cord Furthermore to provide protection against excessive energy being drawn from the main supply in case of a fault in the equipment an overc...

Page 9: ...d Web Browser TCP connection HTTPget DOS program or Telnet Simulation for network connectivity Install via RS232 RS485 serial port connection Transfer data from RS232 RS485 serial interface to TCP IP...

Page 10: ...hysical dimensions and installation instructions see Quickstart and Manual for iSeries monitor controller 2 2 Rear Panel of iSeries Meter with Embedded Ethernet Server Figure 2 1 Rear Panel View of i1...

Page 11: ...See Figure 2 3 C4EIT master unit acts as hub Web Server but it cannot initiate an outside connection with RS485 The serial portion of this option is used to slave multiple RS485 units together using...

Page 12: ...y Figure 2 3 shows multi point half duplex RS485 interface connections for the iServer Figure 2 2 Multi point Half Duplex RS485 Wiring Value of the termination resistor is not critical and depends on...

Page 13: ...automatically detect the Rx and Tx lines on a twisted pair Ethernet cable MDI MDIX Auto Cross Therefore to connect an iServer to a PC Hub Switch Router either a straight through or a cross over cable...

Page 14: ...er When you re connected to the LAN from your computer a correspondence table relates your IP address to your computer s physical MAC address The MAC address can be found on the label of your device a...

Page 15: ...igure DHCP server to communicate with DNS in order for the iServer s Host Name to correctly respond If you cannot access the iServer using its Host Name please contact your network administrator to ma...

Page 16: ...will forward the connection to the serial device and it will take the response from the serial device and send it out to the network 2 Port 2000 Once a TCP connection is made to the iServer using por...

Page 17: ...ork multi point is possible 4 2 Command Structure There are different command types associated with communication between the Ethernet Server and your device shown in Table 4 1 which shows the Command...

Page 18: ...haracters to the byte Square brackets indicating optional status enclose this string since some commands contain no data nn are the two ASCII characters for the device Bus Address of RS485 communicati...

Page 19: ...e the same as the iServer s IP address You also need to make sure that your PC s Subnet Mask is 255 255 255 0 This is a good way to access the iServer over the network and make any configuration chang...

Page 20: ...ssword Figure 4 3 iServer LOGIN and ADMINISTRATOR Passwords There are two different access levels 1 LOGIN Password is required to access the iServer s web server unless it s disabled The default passw...

Page 21: ...password is entered the OVERVIEW page will appear which provides a summary of important parameters within the iServer All the fields are read only Figure 4 4a iServer C4EIT OVERVIEW Page Figure 4 4b...

Page 22: ...address from the DHCP server By default the DHCP option is disabled For more information about DHCP see Section 3 3 MAC Address This Indicates the hardware address of the iServer and it s non configur...

Page 23: ...Host Name for an iServer is eit followed by the last four digits of the MAC address of that particular iServer On Windows servers where the DHCP and DNS are separate functions it s very important to c...

Page 24: ...of the iServer s serial port Options are 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 and 460800 bits s The default is 9600 bits s iSeries device maximum Baud Rate is 19 2 kb s Data Bi...

Page 25: ...h the exceptions of 1000 and 2002 which are reserved by the iServer for other purposes port 1000 is described in the previous section and port 2002 is the iServer s Telnet console port The default is...

Page 26: ...ime value This option defines the time interval during which the iServer stores the serial data in its buffer before sending it out to the network Depending on users applications this time must be at...

Page 27: ...Enter 0 if you don t need to limit the length The default is 0 Inactivity Timeout This option impacts Network to Serial and Serial to Network connections The iServer will drop the TCP connection if th...

Page 28: ...ts to one After a successful connection the iServer stops trying to connect to any others If this connection fails the iServer continues to scroll through the table until the next successful connectio...

Page 29: ...it s time from a Network Time Server then the time will be re assigned after the reboot Network Time Server If there is a time server on the network or the Internet the iServer will get the real date...

Page 30: ...mple Network Management Protocol is a protocol used by network management systems to communicate with network devices that respond to SNMP connections for the purpose of problem detections and correct...

Page 31: ...Email Service This option enables the email service on the iServer The iServer uses SMTP Simple Mail Transfer Protocol with port number 25 to send emails The default is unchecked You must have an emai...

Page 32: ...n the iServer s IP Address is changed iServer Accessed Email This option enables iServer to send an email when the iServer is accessed on Port 2000 iServer Accessed Trap This option enables iServer to...

Page 33: ...cell phone number and xxxx xxx is the domain name for the telecomm provider You ll just need to find the correct email format for your cell phone provider Here are a few examples of email formats for...

Page 34: ...red The password length can be up to 16 alphanumeric case sensitive characters To change the password click on change Empty box means no password is required The default Administrator Password is 0000...

Page 35: ...e with the iServer If the table is empty then all the network nodes will be allowed to connect to the iServer If enabled all packets from IP Addresses that are not on this list will be ignored and thr...

Page 36: ...erial port and will receive the responses from those devices Clicking on Readings page link will show the response On this page there is a Device Number column No which has numbers from 1 to 8 These n...

Page 37: ...The iServer will send this command to the serial device as soon as the READINGS page link is clicked Default is blank Setpoint This field is where the setpoint command is typed Response unit This fie...

Page 38: ...ng on Readings page link will show the response You can setup and display your device s different values e g Peak and Valley Refer to your device s Serial Communication Manual for a list of Commands O...

Page 39: ...l send this command to the serial device as soon as the READINGS page link is clicked Default is blank Setpoint This field is where the setpoint command is typed Response unit This field is the respon...

Page 40: ...ADINGS Page C4EIT Auto Update To change the time interval of the page refresh enter the amount of seconds in the box If you want to manually refresh the page refresh your browser or click on Readings...

Page 41: ...s you type the characters the characters will be transmitted out from the serial port of the iServer If you want to send the whole command as a word simple paste the word in the same area This is an e...

Page 42: ...the name of the file you plan to use click on Check File Name button If OK a new screen will appear and you can then browse to the actual upgrade firmware file iSeries_EIT_x bin and click on the Uploa...

Page 43: ...re reboot a message will appear asking if you are sure you want to proceed with the reboot If you choose to reboot please wait 15 seconds before reconnecting 4 5 12 Diagnostics This page provides diag...

Page 44: ...by the iServer ICMP Transmitted ICMP packets transmitted by the iServer The Reset Counter button can be clicked and the number of bytes received and transmitted of TCP UDP or ICMP will reset to 0 4 5...

Page 45: ...it Tx yellow Serial Receive Rx green Power green Processor CPU ARM7 72 MHz Processor Memory 512 Kbyte Flash 32 Kbyte SRAM Embedded Web Server Serves dynamic Web pages and Java applets Management Devic...

Page 46: ...4x IP65 front bezel i16D NEMA 1 Type 1 front bezel i8 i8DH i8DV Dimensions i 8 Series 48 H x 96 W x 127 mm D 1 89 x 3 78 x 5 i 16 Series 48 H x 48 W x 127 mm D 1 89 x 1 89 x 5 Panel Cutout i 8 Series...

Page 47: ...ame eitxxxx x last 4 digits from the MAC address Protocol TCP Web Server Port 80 Ethernet Port 10 Mbps half Serial Interface Baud Rate 9600 Data Bit 7 bits Parity Odd Stop Bit 1 bit Flow Control None...

Page 48: ...er Maximum Line to Neutral working voltage is 50 Vac dc This unit should not be used in Measurement Categories II III IV Transients Overvoltage Surge 1 2 50uS pulse Input Power 2500 V Input Power 1500...

Page 49: ...ty that tests the network connectivity It is used to determine if the host is capable of exchanging information with another host Port number Socket number is a way to identify a specific process to w...

Page 50: ...pport approximately 216 65 536 computers per network The IP addresses range in binary from 10000000 00000000 xxxxxxxx xxxxxxxx to 10111111 11111111 xxxxxxxx xxxxxxxx The IP addresses range in decimal...

Page 51: ...Mask Dotted Notation Mask Binary Mask Bits Class A 255 0 0 0 Default 0 255 192 0 0 2 255 224 0 0 3 255 240 0 0 4 255 248 0 0 5 255 252 0 0 6 255 254 0 0 7 255 255 0 0 8 255 255 128 0 9 255 255 192 0...

Page 52: ...01010010 DC3 19 13 00010011 S 83 53 01010011 DC4 20 14 00010100 T 84 54 01010100 NAK 21 15 00010101 U 85 55 01010101 SYN 22 16 00010110 V 86 56 01010110 ETB 23 17 00010111 W 87 57 01010111 CAN 24 18...

Page 53: ...11 Crtl Q Data Control 1 XON SOH 01 01 Crtl A Start of DC2 18 12 Crtl R Data Control 2 Header STX 02 02 Crtl B Start of Text DC3 19 13 Crtl S Data Control 3 XOFF ETX 03 03 Crtl C End of Text DC4 20 1...

Page 54: ...artment for obtaining an IP address Figure E 1 Assigning an IP Address using iConnect 1 Place the IP address in this box 2 Take the MAC address from the label attached to the bottom of the iServer and...

Page 55: ...e continued d To access the iServer for Configuration Click on the View Webpage button you will access the iServer s home page as shown below Refer to Section 4 4 for more details Figure E 2 Accessing...

Page 56: ...te a directory C iServer HTTPget 2 Copy HTTPget exe and readme_features doc files to this directory 3 Make sure that you are in this directory and then enter the following test program 4 For help exec...

Page 57: ...nt is unchecked the cursor will stay with no line feed C iServer httpget r S 02X01 r 192 168 1 200 2000 02X01262 9 Until time out by the httpget aprox 24sec C iServer httpget r S 02X01 r 192 168 1 200...

Page 58: ...mand to view all ARP cache entries arp a plus IP address Use this command to view ARP cache entries associated with one particular interface on a network with multiple adapters arp g Same as arp a arp...

Page 59: ...onnected to the iServer s serial port Admin Port 2002 Parameters Figure H 1 Tera Term Telnet Connection Screen Figure H 2 Telnet Setup The default password for Telnet Login is 00000000 and can be chan...

Page 60: ...00000000 iSeries Available Commands 1 RESET To reboot the device 2 FACTORY To restore factory defaults 3 Help This screen 4 c confirm settings and write to the flash 5 p Print the settings 6 q Quite...

Page 61: ...lphanumeric chars SP Admin password 0 16 Alphanumeric chars PP Local port password 0 16 Alphanumeric chars TC Telnet console access 0 Disable 1 Enable WS webserver access 0 Disable 1 Enable SR Secured...

Page 62: ...s ATM machines time attendance terminals medical lab equipments electronic signboards and many others that are directly connected to PCs via their serial ports These devices can be attached to shared...

Page 63: ...s URL location i e 192 168 1 50 followed by an Enter key You should then see the iServer s main WEB page 3 Click on the OK button after entering the LOGIN password 4 On the SERIAL page under Serial Po...

Page 64: ...ion see Figure I 3 set the Connection Type to Simultaneous Sequential enter the Remote IP address would be the IP address of the remote iServer 192 168 1 50 and use the default Remote Port number 2000...

Page 65: ...Appendix I Remote Access Tunneling continued I 2 Local iSeries EIT C4EIT continued Figure I 3 SERIAL Multi Host Connection C4EIT 59...

Page 66: ...If successful this should prove a valid LAN connection For serial tunneling open a HyperTerminal session on the PC pointing to the same COM port to which the Local iServer is connected and type send s...

Page 67: ...port redirecting software Its function is to redirect connections that are destined for a local serial COM port on a PC to an iServer network enabling device on the LAN In a direct serial connection...

Page 68: ...ntrol Panel window By double clicking on this icon you can start the application and the iPORT main window will appear on your screen see Figure J 3 Click on COM Ports button and you will see the wind...

Page 69: ...ed to the Ethernet LAN on the other end The iServer s default IP address is 192 168 1 200 which can be changed to fit your network IP address range see Section 4 iServer Port Number This is the port n...

Page 70: ...ong with the IP address of the iServer shown in the Status window Apply button To save the configuration for a selected COM port click on the Apply button and reboot your PC for settings to take place...

Page 71: ...networked PC This software is compatible with Windows 95 98 NT 2000 XP Windows Vista and Windows 7 32 and 64 bit c If you have Excel 2007 or higher when installing iLog choose Custom installation opti...

Page 72: ...X SD 3 column iTHX W Dual Probe 1st probe 3 column 6 column iSE TC iSD TC 3 column 5 column iSE TH iSD TH 3 column 5 column iBTHX W iBTHX D 3 column 4 column iBTX M iBTX SD 2 column iPTX W 2 column iT...

Page 73: ...e out setting 10006 Windows socket was closed 10007 Windows socket error Wrong IP or wrong Port number was used 10008 The iServer failed to respond to a request Wrong IP or wrong Port number was used...

Page 74: ..._______________________________________________________________ ______________________________________________________________________________ _________________________________________________________...

Page 75: ..._______________________________________________________________ ______________________________________________________________________________ _________________________________________________________...

Page 76: ..._______________________________________________________________ ______________________________________________________________________________ _________________________________________________________...

Page 77: ..._______________________________________________________________ ______________________________________________________________________________ _________________________________________________________...

Page 78: ..._______________________________________________________________ ______________________________________________________________________________ _________________________________________________________...

Page 79: ...ONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications...

Page 80: ...tors R Turbine Paddlewheel Systems R Totalizers Batch Controllers pH CONDUCTIVITY R pH Electrodes Testers Accessories R Benchtop Laboratory Meters R Controllers Calibrators Simulators Pumps R Industri...

Reviews: