Appendix H
Telnet Setup (continued)
s
Is the configuration command, used to set a new setting (see the
example in
Figure I-3
)
RESET
Following with a return character, it will recycle the Power on the
iServer.
FACTORY
Following with a return character, it will set the iServer to it’s factory
default settings.
c
The current settings will be stored permanently .
q
quit
Administrator Password?00000000
iSeries>?
Available Commands:
1. RESET
(To reboot the device)
2. FACTORY
(To restore factory defaults)
3. ?
(Help/This screen)
4. c
(confirm settings and write to the flash)
5. p
(Print the settings)
6. q
(Quite this console)
7. s-<ARG><VALUE>
(To change device settings)
+-------------------------------------------------------------+
| Arg | Description
| Value
|
+-------------------------------------------------------------+
| BD
| BaudRate
| 1-300, 2-600, 3-1200,
|
|
|
| 4-2400, 5-4800, 6-9600,
|
|
|
| 7-19200, 8-38400
|
|
|
| 9-57600, 10-115200,
|
|
|
| 11-230400, 12-460800
|
| DT
| Data Bits
| 1-5 bits, 2-6 bits,
|
|
|
| 3-7 bits, 4-8 bits
|
| PT
| Parity
| 1-none, 2-even, 3-odd
|
| ST
| Stop Bit
| 1-1 bit, 2-2 bits
|
| FC
| FlowControl
| 1-none, 2-hw, 3-sw
|
| DP
| DHCP
| 0-Disable, 1-Enable
|
| IP
| IP address
|
|
| SM
| Subnet mask
|
|
54