Reference Section: Programming Mode (PRoG)
Navigate to the desired setting. Settings include the following:
•
No
– Do not require a password for
PRoG
Mode (factory default)
•
yES
– Require a password for
PRoG
Mode; users will be prompted for this password
when selecting
PRoG
Select the indicated setting.
If
yES
, set the numeric password from the range 0000–9999.
Confirm the password.
5.
Reference Section: Programming Mode (PRoG)
Use Programming Mode to set the following parameters and perform the following functions:
5.1
Setpoint 1 Configuration (PRoG > SP1) ....................................................................................... 35
5.2
Setpoint 2 Configuration (PRoG > SP2) ....................................................................................... 35
5.3
Alarm Mode Configuration (PRoG > ALM.1, ALM.2)................................................................... 36
5.4
Output Channel 1–4 Configuration (PRoG > oUt.1–oUt.4) ......................................................... 40
5.5
PID Configuration (PRoG > PId) ................................................................................................... 43
5.6
Remote Setpoint Configuration (PRoG > RM.SP) ........................................................................ 46
5.7
Multi-Ramp/Soak Mode Parameters (PRoG > M.RMP) .............................................................. 48
5.1
Setpoint 1 Configuration (PRoG > SP1)
Select the Setpoint 1 (
SP1
) parameter.
Set the process goal value for
PId
or
oN.oF
control.
Confirm the value.
5.2
Setpoint 2 Configuration (PRoG > SP2)
Select the Setpoint 2 (
SP2
) parameter.
SP2
is used with Alarm functions and with on/off
control when setting up for Heat/Cool Control Mode.
Navigate to the desired setting. Settings include the following:
•
ASbo
– The value for
SP2
is specified in Absolute Mode (factory default)
•
dEVI
– The value specified for
SP2
indicates an offset (positive or negative) from
SP1
; this allows
SP2
to track any changes to
SP1
automatically
Select the indicated setting.
Set the correct value.
Confirm the value.