Reference Section: Programming Mode (PRoG)
7.
Reference Section: Programming Mode (PRoG)
Use Programming Mode to set the following parameters and perform the following functions:
7.
Reference Section: Programming Mode (PRoG) ................................................................................ 48
7.1
Setpoint 1 Configuration (PRoG > SP1) ....................................................................................... 48
7.2
Setpoint 2 Configuration (PRoG > SP2) ....................................................................................... 48
7.3
Alarm Mode Configuration (PRoG > ALM.1, ALM.2)................................................................... 49
7.4
Output Channel 1
–
6 Configuration (PRoG > oUt.1
–
oUt.6) ......................................................... 53
7.5
PID Configuration (PRoG > PId.S) ................................................................................................ 58
7.6
Remote Setpoint Configuration (PRoG > RM.SP) ........................................................................ 61
7.7
Multi-Ramp/Soak Mode Parameters (PRoG > M.RMP) .............................................................. 64
7.1
Setpoint 1 Configuration (PRoG > SP1)
Select the Setpoint 1 (
SP1
) parameter.
Set the process goal value for
PId
or
oN.oF
control.
Confirm the value.
7.2
Setpoint 2 Configuration (PRoG > SP2)
Select the Setpoint 2 (
SP2
) parameter.
SP2
is used with Alarm functions and with on/off
control when setting up for Heat/Cool Control Mode.
Navigate to the desired setting. Settings include the following:
ASbo
–
The value for
SP2
is specified in Absolute Mode (factory default)
dEVI
–
The value specified for
SP2
indicates an offset (positive or negative) from
SP1
; this allows
SP2
to track any changes to
SP1
automatically
Select the indicated setting.
Set the correct value.
Confirm the value.