Page 26
Feature #1
Current Sensing
(Factory Default Setting Off)
This feature will cause the system to Activate if the control module’s
processor detects current flow within the vehicle’s electrical system. Current
sensing can also be delayed from the standard 3 second Arming Delay to 210
seconds (3 1/2 minutes). Some vehicles present certain factors, such as
delayed lighting or cooling fans, which can activate the current sensing
threshold. Where this is encountered and current sensing is still desired, this
feature’s longer delay setting in many cases will alleviate these problems.
Programming Current Sensing:
Follow Steps 1 to 4 on page 24; at Step 4 the Valet Switch will be pressed
and released one time. The system’s response will be one siren chirp, and
the Status Indicator Light flashing Red once, pausing, then repeating.
Within 10 seconds, press and release the transmitter’s "Arm/Lock" button;
the siren will chirp once to indicate that current sensing is on or press the
“Disarm/Unlock” button and the siren will chirp twice to indicate that
current sensing is off.
Feature #2
3 Or 210 Second Current Sensing Delay
(Factory Default Setting 3 Second)
This feature delays the current sensing operation from the standard 3
second Arming Delay to 210 seconds (3 1/2 minutes). Some vehicles present
certain factors, such as delayed lighting or cooling fans, which can activate
the current sensing threshold. When this is encountered and current sensing
is still desired, this feature’s longer delay setting will alleviate the problems
in many cases.
Programming Current Sensing Delay:
Follow Steps 1 to 4 on page 24; at Step 4 the Valet Switch will be pressed
and released two times. The system’s response will be two siren chirps, and
the Status Indicator Light flashing Red twice, pausing, then repeating.
Within 10 seconds, press and release the transmitter’s "Arm/Lock" button;
the siren will chirp once to indicate the “210 second” setting or press the
“Disarm/Unlock” button and the siren will chirp twice to indicate the “3
second” setting.