14 Pin Secondary Wire Harness (cont’d)
MANUAL TRANSMISSION CONNECTION:
The Gray wire also serves as a door
pin input (must see all doors) which is required to perform the “manual transmission
setup procedure” (detailed in the operation guide). Diode isolate the hood input from
the door input using two 1 or 2 amp diodes facing the cathodes (stripes) towards the
vehicle wires. If the vehicle’s door pin wire is positive, you must invert the signal with
a relay.
YELLOW - ALARM IGNITION CONTROL (+) OUTPUT
This output controls the ignition input to an outboard aftermarket alarm or keyless
entry. When remote start is activated, this wire prevents the keyless/alarm from
receiving an ignition ON input to allow for keyless entry operation. Otherwise, it’s a
direct pass through of the ignition circuit.
CONNECTION:
Connect this wire directly to the outboard keyless entry/alarm’s
ignition input wire.
WHITE/BLUE WIRE - REMOTE START ACTIVATION (-) INPUT
This input will activate the system’s remote start function when it receives a nega
-
tive pulse. Another pulse during remote start operation will turn off the remote start.
CONNECTION:
Connect this wire to any device that you desire to activate the
remote start feature. It requires a negative pulse input.
LT. GREEN/RED WIRE - OEM ALARM ARM (-) OUTPUT
This output provides a 250mA negative pulse when remote start is turned off and
when the system’s alarm is armed.
CONNECTION:
Connect this wire to the vehicle’s OEM alarm arm circuit. Typically,
it will show ground when the door cylinder key is turned to the lock position.
RED/WHITE WIRE - TRUNK RELEASE / CH2 (-) OUTPUT
This output provides a 250mA negative output when the trunk release/CH2 func
-
tion is activated by the controller. The output will remain as long as the controller
button(s) is held.
CONNECTION:
Connect this wire to the vehicle’s existing trunk release switch if it
is a low current negative circuit. If the circuit is a high current ground or a positive
circuit, the use of a relay is required.
This output provides a 250mA negative pulse when remote start is activated and
when the system’s alarm is disarmed.
CONNECTION:
Connect this wire to the vehicle’s OEM alarm disarm circuit. Typi
-
cally, it will show ground when the door cylinder key is turned to the unlock position.
LT. GREEN/BLACK WIRE - OEM ALARM DISARM (-) OUTPUT
These ports provide a direct digital interface for any interface module, or other ac
-
cessories, using either the DBI protocol or iDatalink protocol.
UPON THE FIRST RE-
MOTE START ATTEMPT, THE PORT WILL AUTO-DETECT WHICH PROTOCOL
TO USE. MAKE SURE ANY CONNECTED DEVICE IS PROPERLY CONNECTED
AND PROGRAMMED BEFORE HAND.
The Black port allows firmware
flashing and feature programming via www.omegaweblink.com.
Green & Black Data Ports
8