Filter Constant sets the level of digital filtering according to the following chart. 

Digital Filtering

.  The illustration above demonstrates the effect of digital filtering 

(set with Filter Constant) on module response to a temperature 

change. 

I/O Register Map 

Registers 

Description 

%I1 to %I24 

Digital Inputs 

%I32 

Output Fault 

%I25 to %I31 

Reserved 

%Q1 to %Q16 

Digital outputs 

%Q17 

Clear HSC1 accumulator to 0 

%Q18 

Totalizer: Clear HSC2 

Quadrature 1-2: Accumulator 1 

Reset to max – 1 

%Q19 

Clear HSC3 Accumulator to 0 

%Q20 

Totalizer: Clear HSC4 

Quadrature 3-4: Accumulator 3 

Reset to max – 1 

%Q21 to %Q32 

Reserved 

%AI1 to %AI4 

Analog inputs 

%AI5, %AI6 

HSC1 Accumulator 

%AI7, %AI8 

HSC2 Accumulator 

%AI9, %AI10 

HSC3 Accumulator 

%AI11, %AI12 

HSC4 Accumulator 

 

 

%AQ1, %AQ2 

PWM1 Duty Cycle 

%AQ3, %AQ4 

PWM2 Duty Cycle 

%AQ5, %AQ6 

PWM Prescale 

%AQ7, %AQ8 

PWM Period 

%AQ9 to %AQ14 

Analog outputs 

Note:

  Not all XL6 units contain the I/O listed in this table. 

Registers 

PWM 

HSC 

Stepper 

%AQ1 

Start 

Frequency 

%AQ2 

PWM1 Duty 

Cycle 

(32 bit) 

HSC1 

Preset 

Value 

Run 

Frequency 

%AQ3 

%AQ4 

PWM2 Duty 

Cycle 

(32 bit) 

HSC2 

Preset 

Value 

Accel Count 

(32 bit) 

%AQ5 
%AQ6 

PWM Prescale 

(32 bit) 

Run Count 

(32 bit) 

%AQ7 
%AQ8 

PWM Period 

(32 bit) 

Decel Count 

(32 bit) 

 

 

 

 

%Q1 

 

 

Run 

%I30 

Ready/Done 

%I31 

 

 

Error 

All applicable codes and standards need to be foll owed in the installation of this product.   

Adhere to the following safety precautions whenever any type of connection is  made to the 

module:  

Connect  the  safety  (earth)  ground  on  the  power  connector  first  before  making  any  other 

connections. 

 When connecting to electric circuits or pulse-initiating equipment, open their related breakers. 

 Do not make connections to live power lines. 

 Make connections to the module first; then connect to the circuit to be monitored. 

 Route power wires in a safe manner in accordance with good practice and local codes. 

Wear  proper  personal  protective  equipment  including  safety  glasses  and  insulated  gloves 

when making connections to power circuits. 

 Ensure hands, shoes, and floors are dry before making any connection to a power line. 

 Make sure the unit is turned OFF before making connection to terminals. 

 Make sure all circuits are de-energized before making connections. 

 Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately 

if defective.  

 Use Copper Conductors in Field Wiring Only, 60/75° C 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous 

locations only

WARNING

 – 

EXPLOSION HAZARD

 – Do not disconnect equipment unless power has been 

switched off or the area is known to be non-hazardous. 

AVERTISSEMENT - RISQUE D'EXPLOSION

 - AVANT DE DECONNECTOR L'EQUIPMENT, 

COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON 
DANGEREUX.

WARNING:

  To avoid the risk of electric shock or burns, always connect the safety (or earth) 

ground before making any other connections.  

WARNING:

  To reduce the risk of fire, electrical shock, or physical injury it is strongly 

recommended to fuse the voltage measurement inputs.  Be sure to locate fuses as close to the  

source as possible. 

WARNING:

  Replace fuse with the same type and rating to provide protection against risk of fire 

and shock hazards.   

WARNING:

  In the event of repeated failure, do not replace the fuse again as a repeated failure 

indicates a defective condition that will not clear by replacing the fuse.  

WARNING – EXPLOSION HAZARD

 – Substitution of components may impair suitability for 

Class I, Division 2 

AVERTISSEMENT - RISQUE D'EXPLOSION

 - LA SUBSTITUTION DE COMPOSANTS PEUT 

RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1, 

DIVISION 2  

WARNING 

- The USB parts are for operational maintenance only. Do not leave permanently 

connected unless area is known to be non-hazardous.

  

WARNING

 – 

EXPLOSION HAZARD

 - BATTERIES MUST ONLY BE CHANGED IN AN AREA 

KNOWN TO BE NON-HAZARDOUS 

AVERTISSEMENT - RISQUE D'EXPLOSION

 - AFIN D'EVITER TOUT RISQUE D'EXPLOSION, 

S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX AVANT DE 

CHANGER LA BATTERIE

WARNING

 - Battery May Explode If Mistreated. Do Not Recharge, Disassemble or Dispose Of In 

Fire 

WARNING:

  Only qualified electrical personnel familiar with the construction and operation of this 

equipment and the hazards involved should install, adjust, operate, or service this equipment.  
Read and understand this manual and other applicable manuals in their entirety before 
proceeding.  Failure to observe this precaution could result in severe bodily injury or loss of life. 

60

20

100

40

80

20

0

10

100

90

80

70

60

50

40

30

Scans

0

1

2

3

4

5

6

0

7

%

C

om

pl

et

e

[

]

Filter

Constant

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions: 

1.  This device may not cause harmful interference. 
2.  This device must accept any interference received, including interference that may 

cause undesired operation.  

Radiated Emission Compliance

: For compliance requirement, a ferrite (Horner P/N FBD006 

supplied with the unit) needs to be placed on the AC/DC line with one loop. 

Warning:

  Consult 

user documentation. 

Warning:

  Electrical 

Shock Hazard. 

Safety 

When found on the product, the following symbols specify: 

Summary of Contents for HE-XL103

Page 1: ...atest product manuals omegamanual info User sGuide Shop online at MADE IN HE XL103 Digital DC Inputs 12 Digital Outputs 2 Analog Inputs Medium Resolution HE XL104 24 Digital DC Inputs 16 Digital Outpu...

Page 2: ...ged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0 800...

Page 3: ...d a o L n i M s m 1 e s n o p s e R F F O o t N O None HSC Max Switching Rate 10 kHz Totalizer Pulse Edges 5 kHz Frequency Pulse Width 2 5 kHz Quadrature s m 1 e s n o p s e R N O o t F F O Analog In...

Page 4: ...S 4 Install and tighten the mounting clips provided with the OCS until the gasket material forms a tight seal 5 Connect cables as needed such as communications programming power and CsCAN cables to th...

Page 5: ...move cover CAUTION Do not over tighten screws when replacing the back cover I O Jumpers I O Jumpers JP are located internally To access remove I O cover of unit Wiring Connectors J1 J2 J3 J4 and I O J...

Page 6: ...ased upon the option that is desired Pin MJ1 Pins MJ2 Pins Signal Direction Signal Direction 8 TXD OUT TXD OUT 7 RXD IN RXD IN 6 0 V Ground 0 V Ground 5 5 60mA OUT 5 60mA OUT 4 RTS OUT TX OUT 3 CTS IN...

Page 7: ...ation of I O jumpers JP and wiring connectors J1 J4 Wiring Specifications For I O wiring discrete use the following wire type or equivalent Belden 9918 18 AWG 0 8 mm 2 or larger For shielded Analog I...

Page 8: ...for use in Class I Division 2 Groups A B C and D or Non hazardous locations only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been switched off or the area is known to be non...

Page 9: ...se shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OME...

Page 10: ...Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Indu...

Reviews: