4

Accuracy:

±(0.3%rdg + 3dgts) on 250

W

 range

±(0.3%rdg + 1dgt) on 2.5K

W

 to 2.5M

W

 ranges

±(3.5%rdg + 4dgts) on 25M

W

 range

Open circuit volts

0.4Vdc

Overload protection

500VDC or AC rms

CONTINUITY

Audible indication

<100

W

Overload protection

500VDC or AC rms

DIODE TEST

Accuracy

±(3.0%rdg + 3dgts)

Resolution

1mV

Test current

0.25±0.2mA

Test voltage

<1.6V

CAPACITANCE (Autoranging)

Ranges

250nF,2.5µF,25µF

Accuracy

±(5.0%rdg + 10dgts)

Overload protection

500VDC or AC rms

Summary of Contents for HHM60 Series

Page 1: ...OMEGA HHM63F Digital Multimeter...

Page 2: ...info omega com e mail info omega com Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 20 6418405 FAX 31 20 6434643 Toll Free in Benelux 06 0993344 e mail nl omega com Cz...

Page 3: ...wer mains The unit is intended for use with low energy circuits to 600V AC DC or high energy circuit to 250 VAC or DC 3 Use caution when working above 60V dc or 30V ac rms Such voltages pose a shock h...

Page 4: ...vironment 32 F to 104 F at 70 relative humidity Storage Temperature 4 F to 140 F 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 73 4 F 9 F 75 relative humidity Auto Power off...

Page 5: ...on other ranges Input impedance 10MW Overload protection 600VDC or AC rms AC VOLTS 50Hz 500Hz Ranges 2 5V 25V 250V 600V Resolution 1mV Accuracy 0 75 of reading 4dgts on 2 5V to 600V Input impedance 1...

Page 6: ...lts 0 4Vdc Overload protection 500VDC or AC rms CONTINUITY Audible indication 100W Overload protection 500VDC or AC rms DIODE TEST Accuracy 3 0 rdg 3dgts Resolution 1mV Test current 0 25 0 2mA Test vo...

Page 7: ...wave signal on all range Overload protection 500VDC or AC rms DUTY CYCLE 2Hz to 1kHz Ranges 10 to 90 Resolution 0 1 Accuracy 5dgts 2Vrms min Alternating Pulse signal Pulse Width 50 s Overload protect...

Page 8: ...Power down mode If unused for about 30 minutes the tester will power down automatically If you should diseble Auto Power down mode press SELECT buttom when you turn on the meter Back Light and Data Ho...

Page 9: ...e Function Range switch to the desired voltage function 3 Connect the test leads to the device or circuit being measured 4 For dc a sign is displayed for negative polarity positive polarity is implied...

Page 10: ...to 90 of the frequency duty cycle Resistance Measurements 1 Set the Function Range switch to W W W W W position 2 Remove power from the equipment under test 3 Connect the red test lead to the VW jack...

Page 11: ...displayed in both directions 7 If the junction is measured in a circuit and a low reading is obtained with both lead connections the junction may be shunted by a resistance of less than 1kW In this c...

Page 12: ...the lead to the VW jack and the lead to the COM jack 6 Read the capacitance directly from the display Temperature M easurements 1 Set the Function Range switch to the F position and then press F butt...

Page 13: ...V AAA size batteries The appears on the LCD display when replacement is needed To replace the batteries remove the screw from the back of the meter and lift off the battery cover case Remove the batte...

Page 14: ...use of its various products Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND W...

Page 15: ...ondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEF...

Page 16: ...tor Probes Connectors Panels Assemblies Wire Thermocouple RTD Thermistor Calibrators Ice Point References Recorders Controllers Process Monitors Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTRO...

Reviews: