VI.
COMMANDS FOR MEASUREMENT VALUES:
Command
Receiving value
*01X01
(For all models):
Reading value
.
After reading scale and offset.
Note:
In order to have continuous update on reading. Customer
should send
X01
command every time reading is requested.
Models(TC/RTD/ACV/ACC):
*01X02
Peak reading value.
*01X03
Valley reading.
Models(PR/ST/FP):
*01X03
Peak reading value.
*01X04
Valley reading.
*01V01
(For all models):
String of values.
Received values are in decimal with decimal point and no sign for positive and minus sign for
negative.
Example : 00345.6 or -00345.6
If value is overflowed a “?” will be transmitted along with value (?-99999. or ?999999).
VII. COMMANDS FOR READING MODEL/INPUT TYPE:
Command
Receiving value
*01U01
One byte for model number
VALUE
MODEL
00
FP
01
PR
02
ST
03
TC
04
RTD
05
ACV
06
ACC
Page 16