Output configuration
: Sub-menu that allows you to associate the outputs CN4-8 and CN4-9 with a function, choosing
from: “Pre-alarm”, “Control ON”, “Compressor ON”, “Motor running” and “Compress No Load/Loaded”
Comp. rotation man.:
(to define).
Dryer:
Sub-menu for dryer configuration (see DRYER MENU paragraph).
Condensate drainage:
Sub-menu for dryer configuration (see CONDENSATE DRAINAGE MENU paragraph).
Inverter Menu
Enable Inverter:
Inverter enabling.
% Min functioning:
Defines the frequency minimum percentage at which the inverter must work.
The maximum is 100%
Inverter Integral:
Defines the integral part on the PID calculation of the inverter percentage.
Inverter Proportional:
Defines the proportional part on the PID calculation of the inverter percentage.
Inverter Differential:
Defines the differential part on the PID calculation of the inverter percentage.
Pressure at 100%:
The pressure at which the inverter can work up to 100%
Minimum pressure %:
The pressure at which the inverter must work at the % Min functioning percentage set.
Dryer Menu
Dryer ON:
Dryer
Enabling.
Minimum time
:
Defines the minimum maintenance time of the deactivated dryer. It serves to protect the
dryer compressor from over-frequent start-ups.
Temperature
OFF
:
Defines the value of the temperature at which the dryer compressor is deactivated.
Temp
.
differential
:
Defines the positive differential between the OFF temperature and the re-activation
temperature.
Temperature
offset
:
Defines the difference between the temperature measured and the temperature displayed.
Functioning
mode
:
Defines the functioning mode of the dryer:
Automatic:
The compressor starts and stops based on the main motor of the compressor functioning.
START-UP AND OPERATION
CN4-8=
CN4-9=
Output Configuration
Emergta
Control ON
Back to previous menu not
saved
Saves the configuration and goes back
to the previously saved menu
Changes configuration
Selects the output
to change
Motor running
CN4-8=
CN4-9=
Output Configuration
EEmta
Control ON
Back to previous menu not
saved
Saves the configuration and goes back
to the previously saved menu
Changes configuration
Selects the output
to change
Emergency pressed premuta