background image

 

ELECTRICAL CONNECTIONS 

LOCAL AUTHORITY REQUIREMENTS 

Installation is only permitted by an authorized person, and carried out according to instructions provided by 
the manufacturer.  Incorrect installation might cause harm and damage which the manufacturer accepts no 
responsibility.  The electrical connection can be found 30mm in from the rear edge and 280mm from the left 
hand side (looking from the front). 

INSTALLATION 

This cooktop must be connected to a 220-240V 50Hz power supply. It is earthed via the cord. 
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the 
appliance identification plate) must be checked for correspondence to the available mains supply voltage, 
and the mains electric wiring should be capable of handling the hob’s power rating (also indicated on the 
identification plate); 
The power point must be connected to a suitable earth wiring, in conformity to current safety regulations. 
Ensure that the power supply is within 900mm of the cooktop. The power supply cord must not touch 
against any hot surfaces and must be placed so that its temperature does not exceed 75 degrees C at any 
point along its length. 
The colours of the wires in the hob power cable may not correspond with the colours marked on the 
terminals of your electrical plug .The plug should in any case be wired as follows:   
—connect the green/yellow wire to the terminal marked with the letter E or the earth symbol or coloured 
green/yellow; 
—connect the blue wire to the terminal marked with the letter N or coloured black; 
—connect the brown wire to the terminal marked with the 
letter L or coloured red.
 

After having installed the appliance, the power switch or power plug 
must always be in an accessible position. 

 
Electrical connection diagram 
 
N.B For connections to the mains power supply, never use adapters, reductions or multiple power points as 
these may overheat and catch fire. 
In the event that installation should require modifications to the mains supply wiring system or if the power 
plug is not suitable for the type of power point available, it is required that a qualified technician be called to 
carry out substitution. 
The technician will also have to verify that the cross-section of the electric cables on the power point match 
the appliance’s power rating.   
 

INSTALLATION 

Note: These tops are designed to be fitted into kitchen fixtures measuring 600 mm in depth.    
In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown on the cutting size 
board has to be made, keeping in consideration the following: 
Within the fixture, between the bottom side of the cooker top and the 
upper surface of any other appliance or internal shelf there must be a 
clearance of at least 30 mm;  
Keep at least 200mm from the periphery of the burners to any side or 
rear wall with combustible surfaces or keep the appliance sides at least 
50mm from walls with non-combustible surfaces. 
There must be a distance of at least 650 mm between the hob and any 
extractor hood or wall cupboard positioned immediately above it. The 
distance to an overhead exhaust fan must be at least 750mm. 
The duplicate data plate should be fixed in an accessible position close 
to the appliance (inside face of cupboard door, side of cabinet etc). 
Note: Keep a safe distance away from combustible constructions.   
After installation, all burners should be tested individually and together to 
ensure correct operation. 

 

Summary of Contents for OCG60X

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Gas Cooktops OCG60X OCG64X ...

Page 2: ......

Page 3: ...o avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Omega reserves the right to alter specifications or appearances without notice CONTENTS SECTION PAGE NO Important Safety Instructions 3 Appliance Details 4 Gas Connections 5 6 E...

Page 4: ...llation it must be replaced by the manufacturer it s service agent or similarly qualified persons in order to prevent a hazard 7 The electrical and gas connections must be accessible after installation 8 Electrical connection must be made as per local wiring rules and regulations 9 Ensure that the kitchen is well ventilated or mechanical ventilation is in use while cooking on the gas cooktop 10 DO...

Page 5: ... e g 1 8 for Ø1 80mm injector Semi rapid Burner Semi rapid Burner Wok Burner Auxiliary Burner Table of recommended pot sizes for each burner type Control Knob functions are displayed around each knob as shown below Relevant Sizes LENGTH mm WIDTH mm HEIGHT mm Hob size 580 500 90mm Cut out size 563 483 BURNER TYPE NG DIAMETER OF POT mm ULPG DIAMETER OF POT mm Auxiliary Burner Ø80 TO Ø195 Ø80 TO Ø195...

Page 6: ... and one gasket fitted between the inlet and elbow The hob must be installed in a room with adequate ventilation see installation section N G Fit the supplied NG regulator to the elbow fitting using two spanners note orientation of the NG regulator gas flow Connect the other side of the NG regulator to the gas inlet pipe with the correct BSPT thread connector using two spanners UNIVERSAL L P G Con...

Page 7: ...f a test point REGULATING THE BURNER MINIMUM SETTING When switching from one type of gas to another the minimum flow rate must also be correct The flame should not go out even when passing suddenly from maximum to minimum flame To regulate the flame follow the instructions below Light the burner Set the gas valve to minimum On gas valves provided with adjustment screw in the centre of the shaft fi...

Page 8: ...or coloured red After having installed the appliance the power switch or power plug must always be in an accessible position Electrical connection diagram N B For connections to the mains power supply never use adapters reductions or multiple power points as these may overheat and catch fire In the event that installation should require modifications to the mains supply wiring system or if the pow...

Page 9: ...fan underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhesive on one side Remove burners and grids Turn the cooker top over and rest the top face on a cloth Apply the self adhesive seal G as illustrated in fig 14 Slot the cooker top into the unit and posit...

Page 10: ...erature This will speed up the cooking time and is more efficient In the event of a power outage your gas cooktop can still be used Press turn the desired knob to the High position and light with a match Depress the knob after approx 3 seconds and continue to operate the burner Large utensils exceeding the recommended size can cause excessive heat to reflect back onto the appliance potentially dam...

Page 11: ...t pipes should be checked periodically for leakages see section on leak testing a minimum of every 12 months Lubrication of gas valves This can only be performed by an authorised person It may be required if the gas tap become stiff and difficult to turn Fault Possible cause corrective action No spark No ignition of gas Power outage appliance power turned off at isolation switch fuse blown tripped...

Page 12: ...2018 10 15 ...