INSTALLATION

6) ELECTRICAL CONNECTION

The appliance is supplied with a 1000 mm long

flexible supply lead.

The point of attachment for this lead is located at the

rear  and  on  the  underside  of  the  appliance

380 mm from the right hand side.

The voltage and power consumption are detailed on

the underside of the appliance. Ensure that the

appliance is correctly rated to the supply.

Connect appliance by way of a switched power point

.

THE APPLIANCE MUST BE EARTHED 

Ensure that this power point is properly earthed.

Look  at  the  connection  wiring  diagrams 

(fig. 13).

Warning: in order to avoid any hazard, any

electrical work performed on this equipment or

its associated wiring, should only be done by

persons a qualified by the supplier or similarly

qualified persons.

The socket outlet for this hotplate shall be

installed near the hotplate and shall be easily

accessible.

The electrical connections of the appliance must

be carried out in compliance with the provisions

and standards in force.

Before connecting the appliance, check that:

- The voltage matches the value shown on the

specification plate and the section of the wires of

the electrical system can support the load, which is

also indicated on the specification plate.

- The electrical capacity of the mains supply and

current sockets suit the maximum power rating of

the appliance (consult the data label applied to the

underside of the hotplate).

- The socket or system has an efficient earth

connection in compliance with the provisions and

standards in force. The manufacturer declines all

responsibility for failing to comply with these

provisions.

When  the  appliance  is  connected  to  the

electricity main by a socket:

- Fit a standard plug suited to the load indicated on

the data label to the cable.

- Fit the wires following figure n.12, taking care of

respecting the following correspondences:

Letter L (live) = brown wire;
Letter N (neutral) = blue wire;
Earth symbol 

= green - yellow wire.

- The power supply cable must be positioned so that no

part of it is able to reach an overtemperature of 90 °C.

- Never use reductions, adapters of shunts for

connection since these could create false contacts

and lead to dangerous overheating.

When the appliance is connected straight to the

electricity main:

- Install an omnipolar circuit-breaker between the

appliance and the electricity main. This circuit-

breaker should be sized according to the load

rating of the appliance and possess a minimum 3

mm gap between its contacts.

- Remember  that  the  earth  wire  must  not  be

interrupted by the circuit-breaker.

-The electrical connection may also be protected by

a high sensitivity differential circuit- breaker.

You are strongly advised to fix the relative yellow-

green earth wire to an efficient earthing system.

Before performing any service on the electrical

part of the appliance, it must absolutely be

disconnected from the electrical network.

IMPORTANT: the appliance must be installed

following the manufacturer's instructions. The

manufacturer will not be liable for injury to

persons or animals or property damage caused

by an incorrect installation.

If the installation requires modifications to

the home's electrical system or if the

socket is incompatible with the appliance's

plug,  have  changes  or  replacements

performed by professionally-qualified

person. In particular, this person must also

make sure that the section of the wires of

the  socket  is  suitable  for  the  power

absorbed by the appliance.

FIG. 12

Summary of Contents for OCG755FX

Page 1: ...afety features on the products themselves If your cooktop requires service please contact the Omega customer service centre COD 04077NA 27 10 2017 Dear Customer Thank you for purchasing a Omega Cookto...

Page 2: ...2...

Page 3: ...the version 7 Burner n 1 control knob 8 Burner n 2 control knob 9 Burner n 3 control knob 10 Burner n 4 control knob 11 Burner n 5 control knob Attention this appliance has been manufactured for dome...

Page 4: ...h a flat bottom and in thick metal WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to i...

Page 5: ...anical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you should not to use this appliance any more or replace an o...

Page 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Page 7: ...mm above the top of the burner and no construction shall be within 450 mm above the top of the burner Aminimum depth of 70 mm from the top fig 7 of the worktop surface must be provided for the applia...

Page 8: ...the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn...

Page 9: ...hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural Gas installations require the c...

Page 10: ...nce is connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 taking care of respecting the f...

Page 11: ...ve been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on the burne...

Page 12: ...panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models OCG755FX 5...

Page 13: ...t any seals on the regulating or pre regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake...

Page 14: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Page 15: ...After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give...