11
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
a) Data Label
The Data Label is located on the underside of the
hotplate. A duplicate Data Label is supplied to adhere
in an accessible area next to the hotplate. This
hotplate is suitable for Natural Gas and U-LPG Gas;
ensure that the available gas supply matches the
Data Label.
b) Before Leaving
Check that there are no gas leaks, but do not use a
naked flame to detect gas leaks. Ignite all burners
both individually and concurrently to ensure correct
operation of gas valves, burners, ignition and if fitted,
flame failure valves. Turn gas taps to low flame
position and observe stability of the flame. When
satisfied with the hotplate, please instruct the user on
the correct method of operation. In case the
appliance fails to operate correctly after all checks
have been carried out, refer to the authorised service
provider in your area.
7) TAPS
Our taps are suitable for all the gas, they are male
conical type at one way.
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 1).
- Remove knob “M” (fig. 14 and 14/A) of the tap,
which is simply pressed on to its rod. The by-pass
for minimal rate regulation can be: beside the tap
(fig. 14) or inside the shaft. In any case, to access
to regulation, it can be done trought the insertion of
a small screwdriver ‘’D’’ beside the tap (fig. 14) or in
the hole ‘’C’’ inside the shaft of the tap
(fig 14/A). Turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the “Reduced rate” position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-assemble
the several components.
It is understood that only burners operating with
Natural gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with U - LP .
ADJUSTMENTS
FIG. 14
FIG. 14/A
TAPS LUBRIFICATION
Should a tap being blocked, do not
force and ask for Technical
Assistance.