3.3 ELECTRIC CONNECTION AND SECURITY
During the electric connection, surely follow the instructions below.
The earthing cable must be connected to the terminal. You have to ensure the
cable with insulation to be connected to the power source during the connection of
cable. If there is not any appropriate earthed electric outlet in accordance with
regulations in the place where the appliance will be installed, immediately contact to
our authorized service.
The earthed electric outlet must be close to the appliance. Surely do not use the
extension cord.
The supply cable must not touch to the hot surface of the product.
In case the supply cable is damaged, surely contact to Qualified Service. The
cable must be changed by the authorized service.
The wrong electric connection may damage your appliance. Such damage is not
in guarantee extent.
The appliance is adjusted as appropriate for 220-240 Volts and 380-415V 3N Volts
of electricity. If the network electricity is different than this informed value, immediately
contact to our authorized service.
The electric cable must not touch to the hot parts of appliance. The electric cable
must not touch the back part of the appliance. Otherwise the electric cable of
appliance may be damaged. And this situation may cause short circuit.
The producer firm declares that it has no responsibility against any kind of damages
and losses that emanate from the following security norms.
Provide a means of disconnection from the supply having an air gap contact separation
of at least 3mm in all active (phase) conductors. Such means of disconnection shall be
incorporated in the fixed wiring according to the wiring rules.
The appliance is provided for fixed connection to the power supply. The connection
of the appliance to an electrical source must be done by authorized technician.
For fixed connection, use the H05VV, H05V2V2 or H05RR type supply cord.
For fixed connection, use 3x2,5mm2 or 3x4mm2 sized cable according to appliances
power and terminal box label.
Some appliances can be equipped with special plug (Perilex or Norplug). If it is
necessary, change it with the same specified spare part.
Use 16A/400V 5 pin for perilex plug and 25A/250V for Norplug.
These plugs can be used only in some countries.
If the electrical supply is restricted, means of all-pole disconnection must be accessible
and incorporated in the fixed wiring in accordance with the wiring rules.