Description OM-CP-QUADVOLT
Voltage Range
*See Table Below
Voltage Resolution
Voltage Accuracy
Memory 32,767/channel
Reading Rate 1 reading every second up to 1 reading every 12 hours
LED Indicator None
Channels 4
Required Interface Package IFC110 or IFC200
Baud Rate 2,400
Typical Battery Life 1 year
Operating Environment -40°C to +60°C, 0%RH to 95%RH (non–condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1.0”
(89 mm x 112 mm x 26 mm)
Weight 13 oz (370 g)
OM-CP-QUADVOLT General Specifications
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH,
PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
Specifications subject to change.
See Omega’s terms and conditions at www.omega.com
Still need help?
For more troubleshooting tips and information, refer to the built in help section visit us online at www.omega.com
or contact us for support at 1 (800) 872-9436.
*OM-CP-QUADVOLT Range, Resolution and Calibrated Accuracy
Nominal Range
+-100mV
0 to 2.5V
0 to 15V
0 to 30V
Measurement Range (VDC)
+-150mV
-0.25 to 2.75
-1 to 16
-2 to 32
Accuracy
+-0.01%FSR
+-0.01%FSR
+-0.10%FSR
+-0.10%FSR
Resolution (mV)
5µV
0.1
0.5
1.0
Common Mode Input Range
0 to 2.5V
0 to 2.5V
0 to 2.5V
0 to 2.5V
OM-CP-QUADVOLT and OM-CP-OCTVOLT