Troubleshooting Tips

Why is the wireless data logger not appearing in the software?

If the OM-CP-VOLT101A or OM-CP-VOLT101A-160MV doesn’t appear in the Connected Devices panel, or an 
error message is received while using the OM-CP-VOLT101A or OM-CP-VOLT101A-160MV, try the following: 

 •  Check that the OM-CP-IFC200 is properly connected. For more information, see Troubleshooting    

Interface Cable problems (below).

 •  Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the 

battery of the device. If possible, try switching the battery with a new OM-CP-BAT105. 

 •  Ensure that no other Omega software is running in the background.
 •  Ensure that 

Omega Software

 is being used.

 •  Ensure that the 

Connected Devices 

panel is large enough to display devices. This can be verified by  

positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then  
dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by  
selecting 

File

Options

, and scrolling to the bottom.

Troubleshooting Interface Cable problems 

Check that the software properly recognizes the connected OM-CP-IFC200.

If the data logger is not appearing in the 

Connected Devices

 list, it may be that the OM-CP-IFC200 is not 

properly connected.
1.  In the software, click the 

File

 button, then click 

Options

2.  In the 

Options

 window, click 

Communications

3.  The 

Detected Interfaces

 box will list all of the available communication interfaces. If the OM-CP-IFC200 

is listed here, then the software has correctly recognized and is ready to use it.

Check that Windows recognizes the connected OM-CP-IFC200.

If the software does not recognize the OM-CP-IFC200, there may be a problem with Windows or the USB  
drivers.
1.  In Windows, click 

Start

, right-click 

Computer

 and choose 

Properties

 or press 

Break

 as a key-

board shortcut. 

2.  Click 

Device Manager

 in the left hand column.

3.  Double click 

Universal Serial Bus Controllers

4.  Look for an entry for

 Data logger Interface

.

5.  If the entry is present, and there are no warning messages or icons, then windows has correctly  

recognized the connected OM-CP-IFC200. 

6.  If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be 

installed. These are available on the software flash drive included with the OM-CP-IFC200.

Ensure that the USB end of the OM-CP-IFC200 is securely connected to the computer.

1.  Locate the USB-A plug of the OM-CP-IFC200. 
2.  If the interface cable is connected to the PC, unplug it. Wait ten seconds. 
3.  Reconnect the cable to the PC.
4.  Check to make sure that the red LED is lit, indicating a successful connection.

OM-CP-VOLT101A & OM-CP-VOLT101A-160MV

Summary of Contents for OM-CP-VOLT101A

Page 1: ...M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com For latest product manuals www omegamanual info Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop onlin...

Page 2: ...15V and 30V models Single Ended Wiring OM CP VOLT101A 160MVDC Differential Wiring Two position removable screw terminal connections accepts 2 wire configurations Three position removable screw termina...

Page 3: ...be that the OM CP IFC200 is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all...

Page 4: ...rs appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start store...

Page 5: ...inals and verify it is secure 4 Screw the enclosure back together securely Note Be sure not to over tighten the screws or strip the threads Recalibration The OM CP VOLT101A and OM CP VOLT101A 160MV st...

Page 6: ...FC200 Baud Rate 115 200 Typical Battery Life 10 years at a 15 minute reading rate Operating Environment 40 C to 80 C 40 F to 176 F 0 RH to 95 RH non condensing Enclosure Material ABS plastic Dimension...

Page 7: ...e VDC 160mVDC Measurement Resolution 5 V Calibrated Accuracy 0 01 FSR Memory 1 000 000 readings software configurable memory wrap 330 000 in enhanced start stop mode Reading Rate 4 readings very secon...

Page 8: ...a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installat...

Reviews: