23
Cyclic mode
– for continuous logging. The logger will continue to log once the memory is full
by writing over the first recorded samples.
The memory mode is toggled in the Setup dialog, using the Cyclic Mode checkbox.
When the logger memory is full, the LCD will display
Memory Full
.
Press Menu to pause logger
(when logger is in Run mode)
By pressing the Menu button, the logger will cease to log data until the Menu button is pressed
again from the same screen.
When in
Paused
mode, the user can still scroll through the logger menu screens and use other
features. The user must scroll back to the Pause Logger menu in order to resume the logger
operation.
Reset Unit
When the unit is reset, upon start up it will automatically reconnect to the DataSuite software if a
USB connection is established. In addition, if the logger will continue to operate according to its
last set up instruction. For example, if the logger was in Run mode, then after reset it will
continue to run and record data.
Turn Off Unit / Stop and turn off
Selecting this option will shut the unit down. You can turn the unit on again by pressing the
Scroll
button.
If the logger is in Run mode, selecting this option will first stop the logger, and then turn it off.
It is recommended to turn off the unit when it is not in use.
Min/Max Values Menu
Each sens
or’s minimum/maximum readings (taken from the current logging session) will be
displayed on two rows.
The first row indicates the sensor type, along with the measurement units e.g. V, and the alarm
indication if there is an active alarm on this sensor.
The second row indicates the minimum and maximum measured value and the units. H and L
represent High and Low values, respectively.
4.8.4.
Additional Logger Screens
Loading Firmware
When updating the firmware of the data logger via the software’s Firmware Update Center, the
logger screen will display the update progress. When complete the main logger status screen
will be displayed.
Also refer to
Chapter 6: Updating DataSuite Software and Firmware.
In-
TMP ˚C
26.06H 25.61L