 (4)  SAFETY WARNINGS 

 

  This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, or 

lack of experience or knowledge, unless they have been given 

supervision or instruction concerning the use of the appliance by a 

person responsible for their safety.  Young children should be 

supervised to insure that they do not play with the appliance. 

  If the power cord is damaged, it must be replaced by the 

manufacturer, an authorized service centre or similarly qualified 

persons to avoid a hazard. 

  The exhaust air must not be discharged into a flue which is used for 

exhausting fumes from appliance burning gas or  other fuels (not 

applicable to appliances that only discharge the air back into the 

room). 

  Your cooker hood is for domestic use only, not suitable for 

barbecue, fast - food shops, and other commercial use. 

  Any installation work must be carried out by a qualified electrician or 

competent person. 

  The cooker hood and its filter mesh should be cleaned regularly in 

order to keep in good working order.

 

There is a fire risk if cleaning is 

not carried out in accordance with the instruction. 

  Before cleaning, always ensure that you have switched your cooker 

hood off. 

  Do not flambé underneath range hood. 

  If there is any fault with your cooker hood, please call the customer 

service number in the Warranty Card. 

  Please keep the room adequately ventilated when your cooker hood 

and gas hob are working. 

  Before installation and usage, read all the instructions and make 

sure that the voltage (V) and the frequency (Hz) indicated on your 

cooker hood are exactly the same as the voltage (V) and the 

frequency (Hz) in your home. 

  To ensure that you get the best Warranty experience for your cooker 

hood, please provide copies of the Warranty Card and purchase 

receipt, when booking warranty work with the Customer Service 

department. 

  CAUTION: Accessible parts may become hot when used with 

cooking appliances. 

  Warning: Failure to install the screws or fixing devices in accordance 

with the instructions may result in an electrical hazard. 

Summary of Contents for ORW9XA

Page 1: ...Instructions for the Use and Care and Installation of ORW6XA ORW9XA Wall Canopy Rangehoods ...

Page 2: ......

Page 3: ... to alter specifications or appearances without notice Dispose of packaging responsibly recycle where facilities are available 1 NOTICE 1 Thank you for choosing our cooker hood Please read the instruction manual carefully before use 2 The installation work must be undertaken by a qualified electrician and competent installer 3 The manufacturer disclaims all liability for any damage or injury cause...

Page 4: ...tion and filter design any odours and dust will be absorbed quickly 3 INSTALLATION 1 Before installation please ensure the area is clean to avoid suction of the remaining bits of broken wood and dust 2 The canopy hood cannot share the same air ventilation ducting as other appliances such as gas and electric heaters 3 The bending of the ventilation ducting should be 120 parallel or above the exit v...

Page 5: ...tside chimney bracket on the outside chimney and be sure that the inside chimney can be adjusted in height freely as well as being able to fix the exhaust pipe Afterwards install the exhaust pipe and chimney on the cooker hood See Pic 3 3 4 Lift the cooker hood onto the hook See Pic 4 3 5 Adjust the height of the inside chimney to the position of the inside chimney bracket and fix by screw After a...

Page 6: ... competent person The cooker hood and its filter mesh should be cleaned regularly in order to keep in good working order There is a fire risk if cleaning is not carried out in accordance with the instruction Before cleaning always ensure that you have switched your cooker hood off Do not flambé underneath range hood If there is any fault with your cooker hood please call the customer service numbe...

Page 7: ...sk When replacing the grease filters ensure that the locking mechanism is facing down If the rangehood is used in re circulation mode attach the re circulating kit to the duct and line up to the vent to allow the air escape through the vents The activated charcoal filter must be in place These charcoal filters are designed to absorb cooking odours and are located in the canopy above the grease fil...

Page 8: ...d 3 Push the Mid button the buzzer will buzz once and the motor runs at mid speed 4 Push the High button the buzzer will buzz once and the motor runs at high speed 5 Push the Light button and the two lights will come on Push it again and the light will turn off pic6C Low Mid High Light Stop pic6C Low Mid High Light Stop pic6C Low Mid High Light Stop 6 ...

Page 9: ...dishwasher To do so set the temperature at around 60 degrees 6 2 Notice of cleaning cooker hood A To protect the main body from corrosion over a long period of time the cooker hood should be cleaned with hot water plus non corrosive detergent every two months B Please do not use abrasive detergent for it will damage the body C Keep the motor and other spare parts free from water as this will cause...

Page 10: ...e and seal with silicon rubber Leakage from the connection of U shaped section and cover Take U shaped section down and seal with silicon or paint Shake of the body The fan is damaged and causes shaking Replace the fan The motor is not tightly mounted Lock the motor mounts tightly The body is not tightly hung on wall Fix the body tightly Insufficient suction The distance between the body and the g...

Page 11: ... 8 SPECIFICATIONS Rated Input 220V 240V 50Hz Rated Power 230W Lighting Power 20W X 2 halogen capsule lamp Motor Power 190W Air tube diameter 150MM Air output ORW9XA 730m3 h ORW6XA 705m3 h 9 ...