3-21
Using the Infrared Thermometer/Transmitter
3
String
Description
E:95;
Emissivity is 0.95
MAX:78;
Maximum temperature is 78
MIN:65;
Minimum temperature is 65
DIF:13;
Differential temperature is 13
AVG:72;
Average temperature is 72
HAL:900;
High alarm set point (HAL) is 900
LAL:20;
Low alarm set point (LAL) is 20
AMB:125;
Target ambient temperature is 125
PRN:5;
Data transmission interval is every 5 seconds
PRNF:1;
PRN Flag (0: PRN disabled, No data transmission, 1: PRN enabled,
Data communication active)
IR:73;
Current Infrared temperature is 73
CF:0;
Temperature engineering unit (CF:1 in Degree C, CF:0 in Degree F)
FF:1;
Temperature engineering unit (FF:1 in Degree F, FF:0 in Degree C)
LF:0
Temperature over range flag
xxxx0xxx : In Range, Top
xxxxIxxx : Out of Range, Top
xxxxx0xx : In Range, Bottom
xxxxxIxx : Out of Range, Bottom
End
End of data string